{"id":42311,"date":"2019-10-04T07:08:26","date_gmt":"2019-10-04T06:08:26","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/was-ist-die-ntu-wirksamkeitsmethode-definition\/"},"modified":"2020-03-04T12:32:59","modified_gmt":"2020-03-04T11:32:59","slug":"was-ist-die-ntu-wirksamkeitsmethode-definition","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/","title":{"rendered":"Was ist die NTU-Wirksamkeitsmethode &#8211; Definition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">Bei der NTU-Methode (Number of Transfer Units-Methode) ist die Effektivit\u00e4t das Verh\u00e4ltnis zwischen der tats\u00e4chlichen W\u00e4rme\u00fcbertragungsrate und der maximal m\u00f6glichen W\u00e4rme\u00fcbertragungsrate.\u00a0W\u00e4rmetechnik<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>NTU-Wirksamkeitsmethode<\/h2>\n<p>Die\u00a0im vorherigen Abschnitt beschriebene Methode der\u00a0<a title=\"Logarithmische mittlere Temperaturdifferenz - LMTD\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/heat-transfer\/heat-exchangers\/logarithmic-mean-temperature-difference-lmtd\/\"><strong>logarithmischen mittleren Temperaturdifferenz<\/strong><\/a>\u00a0(LMTD) ist bei der W\u00e4rmetauscheranalyse einfach anzuwenden, wenn die Einlass- und Auslasstemperaturen der hei\u00dfen und kalten Fl\u00fcssigkeiten bekannt sind oder aus einer Energiebilanz ermittelt werden k\u00f6nnen.\u00a0Das LMTD-Verfahren eignet sich daher sehr gut zur Bestimmung der Gr\u00f6\u00dfe und Leistung eines W\u00e4rmetauschers.<\/p>\n<p>Wenn keine direkten Kenntnisse des LMTD vorliegen und die NTU-Methode (\u00a0<strong>Number of Transfer Units-Methode<\/strong>\u00a0) verwendet werden kann.\u00a0Diese Methode basiert auf einem dimensionslosen Parameter namens W\u00e4rme\u00fcbertragungseffektivit\u00e4t, definiert als:<\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-21051 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\" alt=\"NTU-Wirksamkeitsmethode - Gleichung\" width=\"368\" height=\"53\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\" \/><\/a><\/p>\n<p>Wie zu sehen ist, ist die\u00a0<em>Wirksamkeit<\/em>\u00a0das Verh\u00e4ltnis zwischen der tats\u00e4chlichen W\u00e4rme\u00fcbertragungsrate und der maximal m\u00f6glichen W\u00e4rme\u00fcbertragungsrate.\u00a0Um die Wirksamkeit eines W\u00e4rmetauschers zu bestimmen, m\u00fcssen wir zuerst die maximal m\u00f6gliche W\u00e4rme\u00fcbertragungsrate q\u00a0<sub>max<\/sub>\u00a0f\u00fcr den W\u00e4rmetauscher\u00a0bestimmen\u00a0.<\/p>\n<p><strong>NTU-Wirksamkeitsmethode<\/strong><\/p>\n<p>Weitere Lekt\u00fcre:<\/p>\n<ol>\n<li>Grundlagen der W\u00e4rme- und Stoff\u00fcbertragung, 7. Auflage.\u00a0Theodore L. Bergman, Frank P. Incropera, Adrienne S. Lavine.\u00a0John Wiley &amp; Sons, Incorporated, 2011. ISBN: 9781118137253.<\/li>\n<li>W\u00e4rme- und Stoffaustausch.\u00a0Yunus A. Cengel.\u00a0McGraw-Hill Education, 2011. ISBN: 9780071077866.<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-accordion\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Dieser Artikel basiert auf der maschinellen \u00dcbersetzung des englischen Originalartikels. Weitere Informationen finden Sie im Artikel auf Englisch. Sie k\u00f6nnen uns helfen. Wenn Sie die \u00dcbersetzung korrigieren m\u00f6chten, senden Sie diese bitte an: translations@nuclear-power.com oder f\u00fcllen Sie das Online-\u00dcbersetzungsformular aus. Wir bedanken uns f\u00fcr Ihre Hilfe und werden die \u00dcbersetzung so schnell wie m\u00f6glich aktualisieren. Danke.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Bei der NTU-Methode (Number of Transfer Units-Methode) ist die Effektivit\u00e4t das Verh\u00e4ltnis zwischen der tats\u00e4chlichen W\u00e4rme\u00fcbertragungsrate und der maximal m\u00f6glichen W\u00e4rme\u00fcbertragungsrate.\u00a0W\u00e4rmetechnik NTU-Wirksamkeitsmethode Die\u00a0im vorherigen Abschnitt beschriebene Methode der\u00a0logarithmischen mittleren Temperaturdifferenz\u00a0(LMTD) ist bei der W\u00e4rmetauscheranalyse einfach anzuwenden, wenn die Einlass- und Auslasstemperaturen der hei\u00dfen und kalten Fl\u00fcssigkeiten bekannt sind oder aus einer Energiebilanz ermittelt werden k\u00f6nnen.\u00a0Das &#8230; <a title=\"Was ist die NTU-Wirksamkeitsmethode &#8211; Definition\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/\" aria-label=\"Mehr dazu unter Was ist die NTU-Wirksamkeitsmethode &#8211; Definition\">Weiterlesen<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[9],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Was ist die NTU-Wirksamkeitsmethode - Definition<\/title>\n<meta name=\"description\" content=\"Bei der NTU-Methode (Number of Transfer Units-Methode) ist die Effektivit\u00e4t das Verh\u00e4ltnis zwischen der tats\u00e4chlichen W\u00e4rme\u00fcbertragungsrate und der maximal m\u00f6glichen W\u00e4rme\u00fcbertragungsrate. W\u00e4rmetechnik\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Was ist die NTU-Wirksamkeitsmethode - Definition\" \/>\n<meta property=\"og:description\" content=\"Bei der NTU-Methode (Number of Transfer Units-Methode) ist die Effektivit\u00e4t das Verh\u00e4ltnis zwischen der tats\u00e4chlichen W\u00e4rme\u00fcbertragungsrate und der maximal m\u00f6glichen W\u00e4rme\u00fcbertragungsrate. W\u00e4rmetechnik\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-04T06:08:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-04T11:32:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/#primaryimage\",\"inLanguage\":\"de\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/\",\"name\":\"Was ist die NTU-Wirksamkeitsmethode - Definition\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/#primaryimage\"},\"datePublished\":\"2019-10-04T06:08:26+00:00\",\"dateModified\":\"2020-03-04T11:32:59+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Bei der NTU-Methode (Number of Transfer Units-Methode) ist die Effektivit\\u00e4t das Verh\\u00e4ltnis zwischen der tats\\u00e4chlichen W\\u00e4rme\\u00fcbertragungsrate und der maximal m\\u00f6glichen W\\u00e4rme\\u00fcbertragungsrate. W\\u00e4rmetechnik\",\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/de\/was-ist-die-ntu-wirksamkeitsmethode-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"de\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/posts\/42311"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/comments?post=42311"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/posts\/42311\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/media?parent=42311"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/categories?post=42311"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/tags?post=42311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}