{"id":45408,"date":"2019-10-18T04:13:59","date_gmt":"2019-10-18T03:13:59","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/was-ist-kavitation-in-kreiselpumpen-definition\/"},"modified":"2020-03-12T07:53:21","modified_gmt":"2020-03-12T06:53:21","slug":"was-ist-kavitation-in-kreiselpumpen-definition","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/","title":{"rendered":"Was ist Kavitation in Kreiselpumpen &#8211; Definition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">Kavitation ist ein unerw\u00fcnschtes Ereignis. Kavitation f\u00fchrt bei Kreiselpumpen zu Bauteilsch\u00e4den (Materialerosion), Vibrationen, Ger\u00e4uschen und Wirkungsgradeinbu\u00dfen. W\u00e4rmetechnik<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<h2><span>Kavitation in Kreiselpumpen<\/span><\/h2>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damaged-impeller-min.png\"><img loading=\"lazy\" class=\"alignright  wp-image-15096 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damaged-impeller-min-300x229.png\" alt=\"Kavitation - besch\u00e4digtes Laufrad-min\" width=\"187\" height=\"143\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damaged-impeller-min-300x229.png\" \/><\/a><span>Die wichtigsten Orte , an\u00a0denen\u00a0<\/span><strong><span>Kavitation<\/span><\/strong><span>\u00a0auftritt ,\u00a0sind in Pumpen,\u00a0<\/span><strong><span>auf\u00a0<\/span><a title=\"Laufrad - Arten von Laufr\u00e4dern\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/centrifugal-pumps\/impeller-types-of-impellers\/\"><span>Laufr\u00e4der<\/span><\/a><span>\u00a0oder Propeller<\/span><\/strong><span>\u00a0.\u00a0Bei Kreiselpumpen resultiert Kavitation aus einer\u00a0<\/span><strong><span>Verringerung des Saugdrucks<\/span><\/strong><span>\u00a0, einer\u00a0<\/span><strong><span>Erh\u00f6hung der Saugtemperatur<\/span><\/strong><span>\u00a0oder einer\u00a0<\/span><strong><span>Erh\u00f6hung der Durchflussmenge<\/span><\/strong><span>\u00a0\u00fcber die f\u00fcr die Pumpe vorgesehene.<\/span><\/p>\n<p><span>Es gibt zwei Grundtypen\u00a0<\/span><strong><span>der Pumpenkavitation<\/span><\/strong><span>\u00a0:<\/span><\/p>\n<div class=\"su-spacer\"><\/div>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Saugkavitation<\/span><\/h2>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/suction-cavitation-impeller-min.png\"><img loading=\"lazy\" class=\"alignright  wp-image-15095 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/suction-cavitation-impeller-min.png\" alt=\"Saugkavitation - Laufrad-min\" width=\"364\" height=\"300\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/suction-cavitation-impeller-min.png\" \/><\/a><strong><span>Saugkavitation<\/span><\/strong><span>\u00a0oder auch\u00a0<\/span><strong><span>klassische Kavitation<\/span><\/strong><span>\u00a0tritt auf, wenn sich eine Pumpe unter\u00a0<\/span><strong><span>Niederdruck-<\/span><\/strong><span>\u00a0oder Hochvakuumbedingungen befindet.\u00a0Wenn die gepumpte Fl\u00fcssigkeit in das Auge einer\u00a0<\/span><a title=\"Kreiselpumpen\" href=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kreiselpumpe-definition\/\"><span>Kreiselpumpe<\/span><\/a><span>\u00a0gelangt\u00a0, wird\u00a0<\/span><strong><span>der Druck erheblich reduziert<\/span><\/strong><span>\u00a0.\u00a0In einigen F\u00e4llen ist der Druckabfall gro\u00df genug, um zu bewirken, dass die Fl\u00fcssigkeit zu Dampf aufblitzt, wenn der\u00a0<\/span><strong><span>lokale Druck<\/span><\/strong><span>\u00a0unter den\u00a0<\/span><strong><span>S\u00e4ttigungsdruck<\/span><\/strong><span>\u00a0f\u00fcr die zu pumpende Fl\u00fcssigkeit f\u00e4llt.\u00a0Am Auge des Laufrads bilden sich\u00a0<\/span><strong><span>Blasen oder Hohlr\u00e4ume,<\/span><\/strong><span>\u00a0und anschlie\u00dfend bewegen sich die gebildeten Dampfblasen in\u00a0<\/span><strong><span>Bereiche mit h\u00f6herem Druck,<\/span><\/strong><span>\u00a0wenn sie sich in Richtung des Pumpenauslasses\u00a0bewegen\u00a0.\u00a0Im Hochdruckbereich wird die<\/span><strong><span>Dampfblasen fallen pl\u00f6tzlich<\/span><\/strong><span>\u00a0an den \u00e4u\u00dferen Teilen des Laufrads zusammen.\u00a0Dies kann zu erheblichen Sch\u00e4den an allen beweglichen Teilen einer Kreiselpumpe f\u00fchren.<\/span><\/p>\n<p><strong><span>Typische Ursachen f\u00fcr Saugkavitation:<\/span><\/strong><\/p>\n<ul>\n<li><span>Die Pumpe l\u00e4uft zu weit rechts auf der\u00a0<\/span><a title=\"Pumpenkopf - Leistungskurve der Kreiselpumpe\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/centrifugal-pumps\/pump-head-performance-curve\/\"><span>Pumpenkurve<\/span><\/a><\/li>\n<li><span>Schlechte Saugbedingungen (\u00a0<\/span><a title=\"Positiver Netto-Saugkopf\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/centrifugal-pumps\/net-positive-suction-head\/\"><span>NPSH-Anforderungen<\/span><\/a><span>\u00a0)<\/span><\/li>\n<li><span>Verstopfung im Rohr auf der Saugseite<\/span><\/li>\n<li><span>Unangemessenes Rohrleitungsdesign<\/span><\/li>\n<li><span>Verstopfte Filter oder Siebe<\/span><\/li>\n<\/ul>\n<p><span>Um diese Art von Kavitation zu vermeiden\u00a0, muss der im System\u00a0<\/span><strong><span>verf\u00fcgbare Netto-Positivsaugkopf (NPSHa)\u00a0<\/span><\/strong><strong><span>h\u00f6her sein als<\/span><\/strong><span>\u00a0der\u00a0<\/span><strong><span>erforderliche NPSH<\/span><\/strong><span>\u00a0der Pumpe.\u00a0Dieses Problem ist typisch f\u00fcr\u00a0<\/span><strong><span>Saugkavitation<\/span><\/strong><span>\u00a0und daher wird diese Art der Kavitation auch als\u00a0<strong>unzureichende NPSHa-Kavitation bezeichnet<\/strong>\u00a0.<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Net-Positive-Suction-Head-chart.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-15002 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Net-Positive-Suction-Head-chart.png\" alt=\"Positiver Netto-Saugkopf\" width=\"654\" height=\"356\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Net-Positive-Suction-Head-chart.png\" \/><\/a><\/p>\n<p><span>Neben dem Pumpenwechsel k\u00f6nnen Probleme mit der Saugkavitation auch gel\u00f6st werden durch:<\/span><\/p>\n<ol>\n<li><span>Temperatur senken<\/span><\/li>\n<li><span>Reduzierung der Motordrehzahl wenn m\u00f6glich<\/span><\/li>\n<li><span>Vergr\u00f6\u00dferung des Augendurchmessers des Laufrads<\/span><\/li>\n<li><span>Verwendung eines Laufradinduktors.<\/span><\/li>\n<li><span>Verwendung von zwei parallelen Pumpen mit geringerer Leistung.<\/span><\/li>\n<li><span>Verwendung einer Druckerh\u00f6hungspumpe zur Speisung der Hauptpumpe.<\/span><\/li>\n<\/ol>\n<p><span>Ein Sonderfall der Kavitation tritt auf der Saugseite aufgrund ungeeigneter Rohrleitungen in der Saugleitung auf.\u00a0Die Verwendung von Einschr\u00e4nkungen, scharfen\u00a0<\/span><a title=\"Flow durch Elbow - Minor Loss\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/minor-head-loss-local-losses\/flow-through-elbow-minor-loss-2\/\"><span>Ellbogen<\/span><\/a><span>\u00a0und andere hydraulische Ger\u00e4te k\u00f6nnen\u00a0<\/span><a title=\"Turbulente Str\u00f6mung\" href=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-turbulente-stromung-definition\/\"><strong><span>turbulize die flie\u00dfen<\/span><\/strong><\/a><span>\u00a0, dies zu Kavitation Bildung beitragen k\u00f6nnen.<\/span><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\"><\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Entladungskavitation<\/span><\/h2>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/discharge-cavitation-pump-min.png\"><img loading=\"lazy\" class=\"alignright size-full wp-image-15094 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/discharge-cavitation-pump-min.png\" alt=\"Abflusskavitation - Pumpe-min\" width=\"298\" height=\"321\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/discharge-cavitation-pump-min.png\" \/><\/a><strong><span>Entladungs Kavitation<\/span><\/strong><span>\u00a0tritt auf,\u00a0wenn der\u00a0<\/span><strong><span>Pumpenabgabedruck<\/span><\/strong><span>\u00a0ist\u00a0<\/span><strong><span>sehr hoch<\/span><\/strong><span>\u00a0oder wenn die Entladungsstr\u00f6mung beschr\u00e4nkt und die Pumpe nicht verlassen kann (zB durch geschlossene Auslassventil verursacht).\u00a0Ein extrem hoher F\u00f6rderdruck f\u00fchrt dazu, dass der Gro\u00dfteil des gepumpten Fluids\u00a0<\/span><strong><span>in der Pumpe zirkuliert<\/span><\/strong><span>\u00a0.<\/span><\/p>\n<p><span>Diese Art der Kavitation stammt aus zwei Quellen.\u00a0Erstens wird diese\u00a0<\/span><strong><span>innere Zirkulation<\/span><\/strong><span>\u00a0(von Hochdruckzonen in Niederdruckzonen) mit\u00a0<\/span><strong><span>hoher Geschwindigkeit<\/span><\/strong><span>\u00a0durch das Spiel zwischen dem Laufrad und dem Pumpengeh\u00e4use\u00a0<strong>gedr\u00fcckt,<\/strong>\u00a0was zur Bildung eines\u00a0<\/span><strong><span>Niederdruckbereichs<\/span><\/strong><span>\u00a0(aufgrund des\u00a0<\/span><a title=\"Bernoulli-Gleichung - Bernoulli-Prinzip\" href=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-bernoullis-gleichung-bernoullis-prinzip-definition\/\"><span>Bernoulli-Prinzips<\/span><\/a><span>\u00a0) in welche Kavitation auftreten kann.\u00a0Zweitens zirkuliert die Fl\u00fcssigkeit in der Spirale der Pumpe und \u00fcberhitzt sich schnell.<\/span><\/p>\n<p><span>In beiden F\u00e4llen hat Kavitation \u00e4hnliche Folgen.\u00a0Die Implosion von Blasen l\u00f6st starke Sto\u00dfwellen aus, die zu vorzeitigem Verschlei\u00df der Laufradspitzen und des Pumpengeh\u00e4uses f\u00fchren.\u00a0Im Extremfall kann durch Aussto\u00dfkavitation die Laufradwelle brechen.<\/span><\/p>\n<p><strong><span>Typische Ursachen f\u00fcr Entladungskavitation:<\/span><\/strong><\/p>\n<ul>\n<li><span>Die Pumpe l\u00e4uft zu weit links in der Pumpenkurve<\/span><\/li>\n<li><span>Verstopfung im Rohr auf der Auslassseite<\/span><\/li>\n<li><span>Verstopfte Filter oder Siebe<\/span><\/li>\n<li><span>Unangemessenes Rohrleitungsdesign<\/span><\/li>\n<\/ul>\n<div class=\"su-spacer\"><\/div>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Kavitationsnummer<\/span><\/h2>\n<p><span>Die\u00a0<\/span><strong><span>Kavitationszahl (Ca)<\/span><\/strong><span>\u00a0oder der\u00a0<\/span><strong><span>Kavitationsparameter<\/span><\/strong><span>\u00a0ist eine dimensionslose Zahl, die bei Durchflussberechnungen verwendet wird.\u00a0Es ist \u00fcblich, anhand der Kavitationszahl zu charakterisieren, wie nahe der Druck im Fl\u00fcssigkeitsstrom am Dampfdruck (und damit am Kavitationspotential) liegt.<\/span><\/p>\n<p><span>Die Kavitationszahl kann ausgedr\u00fcckt werden als:<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-number-equation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-15097 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-number-equation.png\" alt=\"Kavitationszahl - Gleichung\" width=\"157\" height=\"86\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-number-equation.png\" \/><\/a><\/p>\n<p><span>wo<\/span><\/p>\n<p><em><span>CA = Kavitationsnummer<\/span><\/em><\/p>\n<p><em><span>p = lokaler Druck (Pa)<\/span><\/em><\/p>\n<p><em><span>p\u00a0<\/span><\/em><em><sub><span>v<\/span><\/sub><\/em><em><span>\u00a0= Dampfdruck der Fl\u00fcssigkeit (Pa)<\/span><\/em><\/p>\n<p><em><span>\u03c1 = Dichte der Fl\u00fcssigkeit (kg \/ m\u00a0<\/span><\/em><em><sup><span>3<\/span><\/sup><\/em><em><span>\u00a0)<\/span><\/em><\/p>\n<p><em><span>v = Fl\u00fcssigkeitsgeschwindigkeit (m \/ s)<\/span><\/em><\/p>\n<div class=\"su-spacer\"><\/div>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Kavitationssch\u00e4den<\/span><\/h2>\n<p><strong><span>Kavitation<\/span><\/strong><span>\u00a0ist in vielen F\u00e4llen ein unerw\u00fcnschtes Ereignis.\u00a0Bei Kreiselpumpen verursacht Kavitation\u00a0<\/span><strong><span>Sch\u00e4den an Bauteilen<\/span><\/strong><span>\u00a0(Erosion des Materials), Vibrationen, Ger\u00e4usche und einen Wirkungsgradverlust.<\/span><\/p>\n<figure id=\"attachment_15093\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-15093\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damage-min.png\"><img loading=\"lazy\" class=\"size-medium wp-image-15093 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damage-min-300x178.png\" alt=\"Quelle: Wikipedia, CC BY 2.5, https:\/\/commons.wikimedia.org\/wiki\/File:Turbine_Francis_Worn.JPG\" width=\"300\" height=\"178\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damage-min-300x178.png\" \/><\/a><figcaption id=\"caption-attachment-15093\" class=\"wp-caption-text\"><span>Quelle: Wikipedia, CC BY 2.5,<\/span><br \/>\n<span>https:\/\/commons.wikimedia.org\/wiki\/File:Turbine_Francis_Worn.JPG<\/span><\/figcaption><\/figure>\n<p><span>Vielleicht das wichtigste durch Kavitation verursachte technische Problem ist die\u00a0<\/span><strong><span>materiellen Sch\u00e4den<\/span><\/strong><span>\u00a0, dass Kavitationsblasen verursachen kann ,\u00a0wenn sie\u00a0<\/span><strong><span>zusammenbrechen<\/span><\/strong><span>\u00a0in der N\u00e4he einer festen Oberfl\u00e4che.\u00a0Das Zusammenfallen von Kavitationsblasen ist ein heftiger Prozess, der\u00a0<\/span><strong><span>stark lokalisierte Sto\u00dfwellen<\/span><\/strong><span>\u00a0und\u00a0<\/span><strong><span>Mikrojets erzeugt<\/span><\/strong><span>\u00a0.\u00a0Sie zwingen energetische Fl\u00fcssigkeit in sehr kleine Volumina, wodurch Flecken hoher Temperatur entstehen, und diese intensiven St\u00f6rungen erzeugen stark lokalisierte und vor\u00fcbergehende Oberfl\u00e4chenspannungen auf einer festen Oberfl\u00e4che.\u00a0Anzeichen von\u00a0<\/span><strong><span>Erosion<\/span><\/strong><span>\u00a0treten\u00a0aufgrund der Wasserschlagwirkung der kollabierenden Dampfblasen\u00a0als\u00a0<\/span><strong><span>Lochfra\u00df<\/span><\/strong><span>\u00a0auf.\u00a0Es wurde festgestellt, dass die Kavitationsschadensraten schnell\u00a0<\/span><strong><span>ansteigen<\/span><\/strong><span>\u00a0mit der Erh\u00f6hung des Volumenstroms.<\/span><\/p>\n<p><strong><span>Weichere Materialien<\/span><\/strong><span>\u00a0k\u00f6nnen auch durch\u00a0<\/span><strong><span>kurzfristiges<\/span><\/strong><span>\u00a0Auftreten von\u00a0<\/span><strong><span>Kavitation<\/span><\/strong><span>\u00a0besch\u00e4digt werden\u00a0.\u00a0Einzelne Gruben k\u00f6nnen nach einem einzelnen Blasenkollaps beobachtet werden.\u00a0Daher werden f\u00fcr\u00a0<\/span><strong><span>Kreiselpumpen<\/span><\/strong><span>\u00a0h\u00e4rtere Materialien verwendet\u00a0.\u00a0Bei den h\u00e4rteren Materialien, die in den meisten Anwendungen verwendet werden, kann die\u00a0<\/span><strong><span>zyklische Beanspruchung<\/span><\/strong><span>\u00a0aufgrund wiederholter Zusammenbr\u00fcche zu einem\u00a0<\/span><strong><span>lokalen Versagen der Oberfl\u00e4chenerm\u00fcdung f\u00fchren<\/span><\/strong><span>\u00a0.\u00a0Kavitationssch\u00e4den an Metallen haben daher normalerweise den Anschein eines\u00a0<\/span><strong><span>Erm\u00fcdungsversagens<\/span><\/strong><span>\u00a0.<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-bubble-collapse-min.png\"><img loading=\"lazy\" class=\"alignright size-medium wp-image-15092 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-bubble-collapse-min-300x154.png\" alt=\"Kavitation - Blasenkollaps-min\" width=\"300\" height=\"154\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-bubble-collapse-min-300x154.png\" \/><\/a><span>Wenn die Kavitationsblasen zusammenfallen, zwingen sie energetische Fl\u00fcssigkeit in sehr kleine Volumina, wodurch Flecken mit hoher Temperatur erzeugt werden und Sto\u00dfwellen emittiert werden, von denen letztere eine Ger\u00e4uschquelle sind.\u00a0Obwohl das Zusammenfallen eines kleinen Hohlraums ein Ereignis mit relativ niedriger Energie ist, k\u00f6nnen stark lokalisierte Zusammenbr\u00fcche Metalle wie Stahl im Laufe der Zeit erodieren.\u00a0Die durch das Zusammenfallen von Hohlr\u00e4umen verursachte Lochfra\u00dfbildung f\u00fchrt zu einem starken Verschlei\u00df der Bauteile und kann die Lebensdauer eines Propellers oder einer Pumpe erheblich verk\u00fcrzen.<\/span><\/p>\n<p><span>Kavitation wird normalerweise auch begleitet von:<\/span><\/p>\n<ul>\n<li><strong><span>L\u00e4rm.\u00a0<\/span><\/strong><span>Typisches Ger\u00e4usch wird durch kollabierende Hohlr\u00e4ume verursacht.\u00a0Der Ger\u00e4uschpegel, der durch Kavitation entsteht, ist ein Ma\u00df f\u00fcr die Schwere der Kavitation.<\/span><\/li>\n<li><strong><span>Vibration<\/span><\/strong><span>\u00a0.\u00a0Pumpenschwingungen aufgrund von Kavitation sind charakteristisch niederfrequente Schwingungen, die \u00fcblicherweise im Bereich von 0 bis 10 Hz auftreten.<\/span><\/li>\n<li><strong><span>Reduzierung des Pumpenwirkungsgrades<\/span><\/strong><span>\u00a0.\u00a0Eine Abnahme des Wirkungsgrades der Pumpe ist ein zuverl\u00e4ssigeres Zeichen f\u00fcr das Auftreten von Kavitation.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-accordion\">\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Dieser Artikel basiert auf der maschinellen \u00dcbersetzung des englischen Originalartikels. Weitere Informationen finden Sie im Artikel auf Englisch. Sie k\u00f6nnen uns helfen. Wenn Sie die \u00dcbersetzung korrigieren m\u00f6chten, senden Sie diese bitte an: translations@nuclear-power.com oder f\u00fcllen Sie das Online-\u00dcbersetzungsformular aus. Wir bedanken uns f\u00fcr Ihre Hilfe und werden die \u00dcbersetzung so schnell wie m\u00f6glich aktualisieren. Danke.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Kavitation ist ein unerw\u00fcnschtes Ereignis. Kavitation f\u00fchrt bei Kreiselpumpen zu Bauteilsch\u00e4den (Materialerosion), Vibrationen, Ger\u00e4uschen und Wirkungsgradeinbu\u00dfen. W\u00e4rmetechnik Kavitation in Kreiselpumpen Die wichtigsten Orte , an\u00a0denen\u00a0Kavitation\u00a0auftritt ,\u00a0sind in Pumpen,\u00a0auf\u00a0Laufr\u00e4der\u00a0oder Propeller\u00a0.\u00a0Bei Kreiselpumpen resultiert Kavitation aus einer\u00a0Verringerung des Saugdrucks\u00a0, einer\u00a0Erh\u00f6hung der Saugtemperatur\u00a0oder einer\u00a0Erh\u00f6hung der Durchflussmenge\u00a0\u00fcber die f\u00fcr die Pumpe vorgesehene. Es gibt zwei Grundtypen\u00a0der Pumpenkavitation\u00a0: Saugkavitation Saugkavitation\u00a0oder auch\u00a0klassische &#8230; <a title=\"Was ist Kavitation in Kreiselpumpen &#8211; Definition\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/\" aria-label=\"Mehr dazu unter Was ist Kavitation in Kreiselpumpen &#8211; Definition\">Weiterlesen<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[9],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Was ist Kavitation in Kreiselpumpen - Definition<\/title>\n<meta name=\"description\" content=\"Kavitation ist ein unerw\u00fcnschtes Ereignis. Kavitation f\u00fchrt bei Kreiselpumpen zu Bauteilsch\u00e4den (Materialerosion), Vibrationen, Ger\u00e4uschen und Wirkungsgradeinbu\u00dfen. W\u00e4rmetechnik\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Was ist Kavitation in Kreiselpumpen - Definition\" \/>\n<meta property=\"og:description\" content=\"Kavitation ist ein unerw\u00fcnschtes Ereignis. Kavitation f\u00fchrt bei Kreiselpumpen zu Bauteilsch\u00e4den (Materialerosion), Vibrationen, Ger\u00e4uschen und Wirkungsgradeinbu\u00dfen. W\u00e4rmetechnik\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-18T03:13:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-12T06:53:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damaged-impeller-min-300x229.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"4\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/#primaryimage\",\"inLanguage\":\"de\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/cavitation-damaged-impeller-min-300x229.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/\",\"name\":\"Was ist Kavitation in Kreiselpumpen - Definition\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/#primaryimage\"},\"datePublished\":\"2019-10-18T03:13:59+00:00\",\"dateModified\":\"2020-03-12T06:53:21+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Kavitation ist ein unerw\\u00fcnschtes Ereignis. Kavitation f\\u00fchrt bei Kreiselpumpen zu Bauteilsch\\u00e4den (Materialerosion), Vibrationen, Ger\\u00e4uschen und Wirkungsgradeinbu\\u00dfen. W\\u00e4rmetechnik\",\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/de\/was-ist-kavitation-in-kreiselpumpen-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"de\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/posts\/45408"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/comments?post=45408"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/posts\/45408\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/media?parent=45408"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/categories?post=45408"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/de\/wp-json\/wp\/v2\/tags?post=45408"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}