{"id":39662,"date":"2019-09-16T03:50:56","date_gmt":"2019-09-16T02:50:56","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/"},"modified":"2020-01-06T09:59:05","modified_gmt":"2020-01-06T08:59:05","slug":"que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/","title":{"rendered":"\u00bfQu\u00e9 es la correlaci\u00f3n de ebullici\u00f3n nucleada? &#8211; Correlaci\u00f3n de Rohsenow &#8211; Definici\u00f3n"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">Correlaciones de ebullici\u00f3n nucleada &#8211; Correlaci\u00f3n de Rohsenow.\u00a0Rohsenow propuso en 1952 la correlaci\u00f3n m\u00e1s utilizada para la velocidad de transferencia de calor en la ebullici\u00f3n de la piscina de nucleados.\u00a0Ingenieria termal<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Correlaciones de ebullici\u00f3n nucleada &#8211; Correlaci\u00f3n de Rohsenow<\/h2>\n<p>Los reg\u00edmenes de ebullici\u00f3n discutidos anteriormente difieren considerablemente en su car\u00e1cter.\u00a0Tambi\u00e9n hay diferentes correlaciones que describen la transferencia de calor.\u00a0En esta secci\u00f3n revisamos algunas de las correlaciones m\u00e1s utilizadas para la ebullici\u00f3n de nucleados.<\/p>\n<p><strong>Nucleate Pool Hervir<\/strong><\/p>\n<p><strong>Correlaci\u00f3n de Rohsenow<\/strong><\/p>\n<p><strong>Rohsenow<\/strong>\u00a0propuso en 1952 la correlaci\u00f3n m\u00e1s utilizada para la tasa de transferencia de calor en la ebullici\u00f3n de la piscina de nucleados\u00a0:<\/p>\n<p><strong>Correlaci\u00f3n de Rohsenow<\/strong><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Rohsenow-correlation-nucleate-boiling.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-20786 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Rohsenow-correlation-nucleate-boiling.png\" alt=\"Correlaci\u00f3n de Rohsenow - ebullici\u00f3n nucleada\" width=\"403\" height=\"87\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Rohsenow-correlation-nucleate-boiling.png\" \/><\/a><\/p>\n<p><span>d\u00f3nde<\/span><\/p>\n<ul>\n<li><span>q &#8211; flujo de calor de ebullici\u00f3n de la piscina nucleada [W \/ m\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0]<\/span><\/li>\n<li><span>c\u00a0<\/span><sub><span>1<\/span><\/sub><span>\u00a0&#8211; calor espec\u00edfico del l\u00edquido J \/ kg K<\/span><\/li>\n<li><span>\u0394T &#8211; exceso de temperatura \u00b0 C o K<\/span><\/li>\n<li><span>h\u00a0<\/span><sub><span>fg<\/span><\/sub><span>\u00a0\u00a0&#8211; entalp\u00eda de vaporizaci\u00f3n, J \/ kg<\/span><\/li>\n<li><span>Pr &#8211; n\u00famero de l\u00edquido de Prandtl<\/span><\/li>\n<li><span>n &#8211; constante experimental igual a 1 para agua y 1.7 para otros fluidos<\/span><\/li>\n<li><span>C\u00a0<\/span><sub><span>sf<\/span><\/sub><span>\u00a0&#8211; factor de fluido superficial, por ejemplo, el agua y el n\u00edquel tienen un C\u00a0<\/span><sub><span>sf<\/span><\/sub><span>\u00a0de 0.006<\/span><\/li>\n<li><span>\u03bc\u00a0<\/span><sub><span>1<\/span><\/sub><span>\u00a0&#8211; viscosidad din\u00e1mica del l\u00edquido kg \/ ms<\/span><\/li>\n<li><span>g &#8211; aceleraci\u00f3n gravitacional m \/ s\u00a0<\/span><sup><span>2<\/span><\/sup><\/li>\n<li><span>g\u00a0<\/span><sub><span>0<\/span><\/sub><span>\u00a0&#8211; factor de conversi\u00f3n de fuerza kgm \/ Ns\u00a0<\/span><sup><span>2<\/span><\/sup><\/li>\n<li><span>\u03c1\u00a0<\/span><sub><span>1<\/span><\/sub><span>\u00a0&#8211; densidad del l\u00edquido kg \/ m\u00a0<\/span><sup><span>3<\/span><\/sup><\/li>\n<li><span>\u03c1\u00a0<\/span><sub><span>v<\/span><\/sub><span>\u00a0&#8211; densidad de vapor kg \/ m\u00a0<\/span><sup><span>3<\/span><\/sup><\/li>\n<li><span>\u03c3 &#8211; interfaz de tensi\u00f3n superficial-l\u00edquido-vapor N \/ m<\/span><\/li>\n<\/ul>\n<p><span>Como se puede ver, \u0394T \u221d (q)\u00a0<\/span><sup><span>\u2153<\/span><\/sup><span>\u00a0.\u00a0Esta proporcionalidad muy importante muestra la creciente capacidad de la interfaz para transferir calor.<\/span><\/p>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Correlaciones de ebullici\u00f3n nucleada &#8211; Correlaci\u00f3n de Rohsenow.\u00a0Rohsenow propuso en 1952 la correlaci\u00f3n m\u00e1s utilizada para la velocidad de transferencia de calor en la ebullici\u00f3n de la piscina de nucleados.\u00a0Ingenieria termal Correlaciones de ebullici\u00f3n nucleada &#8211; Correlaci\u00f3n de Rohsenow Los reg\u00edmenes de ebullici\u00f3n discutidos anteriormente difieren considerablemente en su car\u00e1cter.\u00a0Tambi\u00e9n hay diferentes correlaciones que describen &#8230; <a title=\"\u00bfQu\u00e9 es la correlaci\u00f3n de ebullici\u00f3n nucleada? &#8211; Correlaci\u00f3n de Rohsenow &#8211; Definici\u00f3n\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/\" aria-label=\"M\u00e1s en \u00bfQu\u00e9 es la correlaci\u00f3n de ebullici\u00f3n nucleada? &#8211; Correlaci\u00f3n de Rohsenow &#8211; Definici\u00f3n\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[16],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfQu\u00e9 es la correlaci\u00f3n de ebullici\u00f3n nucleada? - Correlaci\u00f3n de Rohsenow - Definici\u00f3n<\/title>\n<meta name=\"description\" content=\"Correlaciones de ebullici\u00f3n nucleada - Correlaci\u00f3n de Rohsenow. Rohsenow propuso en 1952 la correlaci\u00f3n m\u00e1s utilizada para la velocidad de transferencia de calor en la ebullici\u00f3n de la piscina de nucleados. Ingenieria termal\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfQu\u00e9 es la correlaci\u00f3n de ebullici\u00f3n nucleada? - Correlaci\u00f3n de Rohsenow - Definici\u00f3n\" \/>\n<meta property=\"og:description\" content=\"Correlaciones de ebullici\u00f3n nucleada - Correlaci\u00f3n de Rohsenow. Rohsenow propuso en 1952 la correlaci\u00f3n m\u00e1s utilizada para la velocidad de transferencia de calor en la ebullici\u00f3n de la piscina de nucleados. Ingenieria termal\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-09-16T02:50:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-01-06T08:59:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Rohsenow-correlation-nucleate-boiling.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"1 minuto\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Rohsenow-correlation-nucleate-boiling.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/\",\"name\":\"\\u00bfQu\\u00e9 es la correlaci\\u00f3n de ebullici\\u00f3n nucleada? - Correlaci\\u00f3n de Rohsenow - Definici\\u00f3n\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/#primaryimage\"},\"datePublished\":\"2019-09-16T02:50:56+00:00\",\"dateModified\":\"2020-01-06T08:59:05+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Correlaciones de ebullici\\u00f3n nucleada - Correlaci\\u00f3n de Rohsenow. Rohsenow propuso en 1952 la correlaci\\u00f3n m\\u00e1s utilizada para la velocidad de transferencia de calor en la ebullici\\u00f3n de la piscina de nucleados. Ingenieria termal\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-correlacion-de-ebullicion-nucleada-correlacion-de-rohsenow-definicion\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"es\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/39662"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/comments?post=39662"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/39662\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/media?parent=39662"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/categories?post=39662"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/tags?post=39662"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}