{"id":39814,"date":"2019-09-16T12:25:59","date_gmt":"2019-09-16T11:25:59","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/"},"modified":"2020-03-04T13:53:29","modified_gmt":"2020-03-04T12:53:29","slug":"que-esta-hirviendo-en-el-reactor-nuclear-definicion","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/","title":{"rendered":"\u00bfQu\u00e9 est\u00e1 hirviendo en el reactor nuclear? Definici\u00f3n"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">Ebullici\u00f3n en Reactor Nuclear.\u00a0En los BWR, la ebullici\u00f3n del refrigerante ocurre en el funcionamiento normal y es un fen\u00f3meno muy deseado.\u00a0Para los PWR en funcionamiento normal, tambi\u00e9n puede producirse ebullici\u00f3n de nucleados.\u00a0Ingenieria termal<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Hervir en reactores nucleares<\/h2>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Hervir en BWR<\/h2>\n<p><strong>En los\u00a0<\/strong><a href=\"https:\/\/www.nuclear-power.com\/bwr-boiling-water-reactor\/\"><strong>BWR, la<\/strong><\/a>\u00a0ebullici\u00f3n del refrigerante ocurre en\u00a0<strong>el funcionamiento normal<\/strong>\u00a0y es un fen\u00f3meno muy deseado.\u00a0Las\u00a0<strong>calidades de flujo<\/strong>\u00a0t\u00edpicas\u00a0en los\u00a0<a href=\"https:\/\/www.nuclear-power.com\/bwr-boiling-water-reactor\/\"><strong>n\u00facleos BWR<\/strong><\/a>\u00a0son del orden del 10 al 20%.\u00a0Un\u00a0<strong>reactor de agua hirviendo<\/strong>\u00a0se enfr\u00eda y\u00a0<a href=\"https:\/\/www.nuclear-power.com\/neutron-moderator\/\">modera<\/a>\u00a0con agua como un PWR, pero a una\u00a0<strong>presi\u00f3n m\u00e1s baja<\/strong>\u00a0(7MPa), lo que permite que el agua\u00a0<strong>hierva dentro del recipiente a presi\u00f3n<\/strong>\u00a0produciendo el vapor que hace funcionar las turbinas.\u00a0Por lo tanto, la evaporaci\u00f3n ocurre directamente en los canales de combustible.\u00a0Por lo tanto, los BWR son el mejor ejemplo para esta \u00e1rea, porque la evaporaci\u00f3n del refrigerante ocurre en la operaci\u00f3n normal y es un fen\u00f3meno muy deseado.<\/p>\n<p>En los BWR existe un fen\u00f3meno que es de la\u00a0<strong>mayor importancia en la seguridad del reactor<\/strong>\u00a0.\u00a0Este fen\u00f3meno se conoce como el\u00a0<strong>&#8220;secado&#8221;<\/strong>\u00a0y est\u00e1 directamente asociado con\u00a0<strong>cambios en el patr\u00f3n de flujo<\/strong>\u00a0durante la evaporaci\u00f3n en la regi\u00f3n de alta calidad.\u00a0En condiciones normales, la superficie del combustible se enfr\u00eda de manera efectiva por medio del refrigerante hirviendo.\u00a0Sin embargo, cuando el flujo de calor excede un\u00a0<strong>valor cr\u00edtico<\/strong>\u00a0(CHF &#8211; flujo de calor cr\u00edtico), el patr\u00f3n de flujo puede alcanzar las\u00a0<strong>condiciones de secado<\/strong>\u00a0(desaparece la pel\u00edcula delgada de l\u00edquido).\u00a0La transferencia de calor desde la superficie del combustible al refrigerante se deteriora, con el resultado de un\u00a0<strong>aumento dr\u00e1stico de la temperatura de la superficie del combustible<\/strong>\u00a0.<\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Hervir en PWR<\/h2>\n<p>Aunque los primeros dise\u00f1os de n\u00facleos supon\u00edan que no se pod\u00eda permitir la ebullici\u00f3n de la superficie en los\u00a0<a title=\"PWR - Reactor de agua a presi\u00f3n\" href=\"https:\/\/www.nuclear-power.com\/pwr-pressurized-water-reactor\/\"><strong>PWR<\/strong><\/a>\u00a0, esta suposici\u00f3n se rechaz\u00f3 pronto y la transferencia de calor en dos fases ahora es uno de los mecanismos de transferencia de calor de operaci\u00f3n normal tambi\u00e9n en los PWR.\u00a0Para los PWR en funcionamiento normal, hay un\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/materials-nuclear-engineering\/properties-steam-what-is-steam\/saturated-and-subcooled-liquid\/\">agua l\u00edquida comprimida<\/a>\u00a0dentro del n\u00facleo del reactor, bucles y generadores de vapor.\u00a0La presi\u00f3n se mantiene a aproximadamente\u00a0<strong>16MPa<\/strong>\u00a0.\u00a0A esta presi\u00f3n, el agua hierve a aproximadamente\u00a0<strong>350 \u00b0 C<\/strong>\u00a0(662 \u00b0 F).\u00a0Como se\u00a0<a title=\"Ejemplo - Convecci\u00f3n - Problema con la soluci\u00f3n\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/heat-transfer\/convection-convective-heat-transfer\/example-convection-problem-with-solution\/\">calcul\u00f3 en el ejemplo<\/a>\u00a0, la temperatura de la superficie T\u00a0<sub>Zr, 1<\/sub>\u00a0= 325 \u00b0 C garantiza que ni siquiera se produce una ebullici\u00f3n subenfriada.\u00a0Tenga en cuenta que, la ebullici\u00f3n subenfriada requiere T\u00a0<sub>Zr, 1<\/sub>\u00a0= T\u00a0<sub>sat<\/sub>.\u00a0Dado que las temperaturas de entrada del agua son generalmente de aproximadamente\u00a0<strong>290 \u00b0 C<\/strong>\u00a0(554 \u00b0 F), es obvio que este ejemplo corresponde a la parte inferior del n\u00facleo.\u00a0A elevaciones m\u00e1s altas del n\u00facleo, la temperatura aparente puede alcanzar hasta 330 \u00b0 C.\u00a0La diferencia de temperatura de 29 \u00b0 C hace que se produzca la ebullici\u00f3n subenfriada (330 \u00b0 C + 29 \u00b0 C&gt; 350 \u00b0 C).\u00a0Por otro lado, la\u00a0<strong>ebullici\u00f3n de nucleados<\/strong>\u00a0en la superficie altera efectivamente la capa estancada y, por lo tanto, la ebullici\u00f3n de nucleados aumenta significativamente la capacidad de una superficie para transferir\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/thermodynamics\/what-is-energy-physics\/internal-energy-thermal-energy\/\">energ\u00eda t\u00e9rmica<\/a>\u00a0al fluido a granel.\u00a0Como resultado, el coeficiente de transferencia de calor por convecci\u00f3n aumenta significativamente y, por lo tanto, a elevaciones m\u00e1s altas, la diferencia de temperatura (T\u00a0<sub>Zr, 1<\/sub>\u00a0&#8211; T a\u00a0<sub>granel<\/sub>\u00a0) disminuye significativamente.<\/p>\n<p>En el caso de los\u00a0<a href=\"https:\/\/www.nuclear-power.com\/pwr-pressurized-water-reactor\/\">PWR<\/a>\u00a0, el problema cr\u00edtico de seguridad se denomina\u00a0<strong>DNB<\/strong>\u00a0(\u00a0<strong>desviaci\u00f3n de la ebullici\u00f3n de los nucleados<\/strong>\u00a0), lo que provoca la formaci\u00f3n de una\u00a0<strong>capa de vapor local<\/strong>\u00a0, lo que provoca una reducci\u00f3n dram\u00e1tica en la capacidad de transferencia de calor.\u00a0Este fen\u00f3meno ocurre en la regi\u00f3n subenfriada o de baja calidad.\u00a0El comportamiento de la crisis de ebullici\u00f3n depende de muchas condiciones de flujo (presi\u00f3n, temperatura, velocidad de flujo), pero la crisis de ebullici\u00f3n ocurre a flujos de calor relativamente altos y parece estar asociada con la nube de burbujas, adyacente a la superficie.\u00a0Estas burbujas o pel\u00edculas de vapor reducen la cantidad de agua entrante.\u00a0Dado que este fen\u00f3meno deteriora el coeficiente de transferencia de calor y el flujo de calor permanece, el calor se\u00a0<strong>acumula<\/strong>en la barra de combustible causando\u00a0<strong>un aumento dram\u00e1tico<\/strong>\u00a0del revestimiento y la\u00a0<strong>temperatura del<\/strong>\u00a0combustible\u00a0.<\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Saturaci\u00f3n en presurizador<\/h2>\n<figure id=\"attachment_16538\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-16538\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Extensive-vs.-Intensive-properties-min.png\"><img loading=\"lazy\" class=\"size-medium wp-image-16538 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Extensive-vs.-Intensive-properties-min-238x300.png\" alt=\"Propiedades termodin\u00e1micas extensivas versus intensivas\" width=\"238\" height=\"300\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Extensive-vs.-Intensive-properties-min-238x300.png\" \/><\/a><figcaption id=\"caption-attachment-16538\" class=\"wp-caption-text\">Propiedades extensivas e intensivas del medio en el presurizador.<\/figcaption><\/figure>\n<p>Un\u00a0\u00a0<a title=\"Presurizador\" href=\"https:\/\/www.nuclear-power.com\/pressurizer\/\"><strong>presuriz<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ebullici\u00f3n en Reactor Nuclear.\u00a0En los BWR, la ebullici\u00f3n del refrigerante ocurre en el funcionamiento normal y es un fen\u00f3meno muy deseado.\u00a0Para los PWR en funcionamiento normal, tambi\u00e9n puede producirse ebullici\u00f3n de nucleados.\u00a0Ingenieria termal Hervir en reactores nucleares Hervir en BWR En los\u00a0BWR, la\u00a0ebullici\u00f3n del refrigerante ocurre en\u00a0el funcionamiento normal\u00a0y es un fen\u00f3meno muy deseado.\u00a0Las\u00a0calidades de &#8230; <a title=\"\u00bfQu\u00e9 est\u00e1 hirviendo en el reactor nuclear? Definici\u00f3n\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/\" aria-label=\"M\u00e1s en \u00bfQu\u00e9 est\u00e1 hirviendo en el reactor nuclear? Definici\u00f3n\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[16],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfQu\u00e9 est\u00e1 hirviendo en el reactor nuclear? Definici\u00f3n<\/title>\n<meta name=\"description\" content=\"Ebullici\u00f3n en Reactor Nuclear. En los BWR, la ebullici\u00f3n del refrigerante se produce en el funcionamiento normal y es un fen\u00f3meno muy deseado. Para los PWR en funcionamiento normal, tambi\u00e9n puede producirse ebullici\u00f3n de nucleados. Ingenieria termal\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfQu\u00e9 est\u00e1 hirviendo en el reactor nuclear? Definici\u00f3n\" \/>\n<meta property=\"og:description\" content=\"Ebullici\u00f3n en Reactor Nuclear. En los BWR, la ebullici\u00f3n del refrigerante se produce en el funcionamiento normal y es un fen\u00f3meno muy deseado. Para los PWR en funcionamiento normal, tambi\u00e9n puede producirse ebullici\u00f3n de nucleados. Ingenieria termal\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-09-16T11:25:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-04T12:53:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Extensive-vs.-Intensive-properties-min-238x300.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"3 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Extensive-vs.-Intensive-properties-min-238x300.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/\",\"name\":\"\\u00bfQu\\u00e9 est\\u00e1 hirviendo en el reactor nuclear? Definici\\u00f3n\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/#primaryimage\"},\"datePublished\":\"2019-09-16T11:25:59+00:00\",\"dateModified\":\"2020-03-04T12:53:29+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Ebullici\\u00f3n en Reactor Nuclear. En los BWR, la ebullici\\u00f3n del refrigerante se produce en el funcionamiento normal y es un fen\\u00f3meno muy deseado. Para los PWR en funcionamiento normal, tambi\\u00e9n puede producirse ebullici\\u00f3n de nucleados. Ingenieria termal\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/es\/que-esta-hirviendo-en-el-reactor-nuclear-definicion\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"es\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/39814"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/comments?post=39814"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/39814\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/media?parent=39814"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/categories?post=39814"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/tags?post=39814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}