{"id":41538,"date":"2019-09-27T09:29:49","date_gmt":"2019-09-27T08:29:49","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/que-es-la-curva-de-vapor-de-saturacion-definicion\/"},"modified":"2020-01-19T19:38:21","modified_gmt":"2020-01-19T18:38:21","slug":"que-es-la-curva-de-vapor-de-saturacion-definicion","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/","title":{"rendered":"\u00bfQu\u00e9 es la curva de vapor de saturaci\u00f3n? Definici\u00f3n"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">Curva de vapor de saturaci\u00f3n.\u00a0La curva de vapor de saturaci\u00f3n es la curva que separa el estado de dos fases y el estado de vapor sobrecalentado en el diagrama Ts.\u00a0Ingenieria termal<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Curva de vapor de saturaci\u00f3n<\/h2>\n<figure id=\"attachment_14172\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-14172\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Boiling-point-of-water.png\"><img loading=\"lazy\" class=\"size-medium wp-image-14172 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Boiling-point-of-water-300x255.png\" alt=\"Diagrama de fase del agua.\" width=\"300\" height=\"255\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Boiling-point-of-water-300x255.png\" \/><\/a><figcaption id=\"caption-attachment-14172\" class=\"wp-caption-text\">Diagrama de fase del agua.<br \/>\nFuente: wikipedia.org CC BY-SA<\/figcaption><\/figure>\n<p>Ver tambi\u00e9n:\u00a0<a title=\"Propiedades de Steam - Qu\u00e9 es Steam\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-steam-propiedades-de-steam-definicion\/\">Steam<\/a><\/p>\n<p>Como se puede ver en el diagrama de fase del agua, en las regiones de dos fases (p. Ej., En el borde de las fases vapor \/ l\u00edquido), la temperatura espec\u00edfica solo establecer\u00e1 la presi\u00f3n y la presi\u00f3n espec\u00edfica establecer\u00e1 la temperatura.<\/p>\n<ul>\n<li>La curva de vapor de saturaci\u00f3n es la curva que separa el estado de dos fases y el estado de vapor sobrecalentado en el diagrama Ts.<\/li>\n<li>La curva de l\u00edquido saturado es la curva que separa el estado l\u00edquido subenfriado y el estado de dos fases en el diagrama Ts.<\/li>\n<\/ul>\n<p>T\u00edpicamente, la mayor\u00eda de\u00a0<strong>las plantas de energ\u00eda nuclear\u00a0<\/strong>\u00a0opera\u00a0<strong>turbinas de vapor de condensaci\u00f3n de etapas m\u00faltiples<\/strong>\u00a0.\u00a0En estas turbinas, la etapa de alta presi\u00f3n recibe vapor (este vapor es vapor casi saturado &#8211; x = 0.995 &#8211; punto C en la figura) desde un generador de vapor y lo expulsa al separador-recalentador de humedad (punto D).\u00a0El vapor debe ser\u00a0<strong>recalentado o sobrecalentado.<\/strong>con el fin de evitar da\u00f1os que puedan ser causados \u200b\u200ba palas de turbina de vapor por vapor de baja calidad.\u00a0El alto contenido de gotas de agua puede causar el impacto r\u00e1pido y la erosi\u00f3n de las cuchillas que ocurre cuando el agua condensada se lanza sobre las cuchillas.\u00a0Para evitar esto, se instalan drenajes de condensado en la tuber\u00eda de vapor que conduce a la turbina.\u00a0El recalentador calienta el vapor (punto D) y luego el vapor se dirige a la etapa de baja presi\u00f3n de la turbina de vapor, donde se expande (punto E a F).\u00a0El vapor agotado est\u00e1 a una presi\u00f3n muy por debajo de la atmosf\u00e9rica, y est\u00e1 en un estado parcialmente condensado (punto F), t\u00edpicamente de una calidad cercana al 90%.<\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/dry-steam-saturated-vapor-min.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-16092 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/dry-steam-saturated-vapor-min.png\" alt=\"vapor seco-saturado-min-vapor\" width=\"633\" height=\"540\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/dry-steam-saturated-vapor-min.png\" \/><\/a><\/p>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Curva de vapor de saturaci\u00f3n.\u00a0La curva de vapor de saturaci\u00f3n es la curva que separa el estado de dos fases y el estado de vapor sobrecalentado en el diagrama Ts.\u00a0Ingenieria termal Curva de vapor de saturaci\u00f3n Diagrama de fase del agua. Fuente: wikipedia.org CC BY-SA Ver tambi\u00e9n:\u00a0Steam Como se puede ver en el diagrama de &#8230; <a title=\"\u00bfQu\u00e9 es la curva de vapor de saturaci\u00f3n? Definici\u00f3n\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/\" aria-label=\"M\u00e1s en \u00bfQu\u00e9 es la curva de vapor de saturaci\u00f3n? Definici\u00f3n\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[16],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfQu\u00e9 es la curva de vapor de saturaci\u00f3n? Definici\u00f3n<\/title>\n<meta name=\"description\" content=\"Curva de vapor de saturaci\u00f3n. La curva de vapor de saturaci\u00f3n es la curva que separa el estado de dos fases y el estado de vapor sobrecalentado en el diagrama T-s. Ingenieria termal\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfQu\u00e9 es la curva de vapor de saturaci\u00f3n? Definici\u00f3n\" \/>\n<meta property=\"og:description\" content=\"Curva de vapor de saturaci\u00f3n. La curva de vapor de saturaci\u00f3n es la curva que separa el estado de dos fases y el estado de vapor sobrecalentado en el diagrama T-s. Ingenieria termal\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-09-27T08:29:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-01-19T18:38:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Boiling-point-of-water-300x255.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"2 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Boiling-point-of-water-300x255.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/\",\"name\":\"\\u00bfQu\\u00e9 es la curva de vapor de saturaci\\u00f3n? Definici\\u00f3n\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/#primaryimage\"},\"datePublished\":\"2019-09-27T08:29:49+00:00\",\"dateModified\":\"2020-01-19T18:38:21+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Curva de vapor de saturaci\\u00f3n. La curva de vapor de saturaci\\u00f3n es la curva que separa el estado de dos fases y el estado de vapor sobrecalentado en el diagrama T-s. Ingenieria termal\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-curva-de-vapor-de-saturacion-definicion\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"es\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/41538"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/comments?post=41538"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/41538\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/media?parent=41538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/categories?post=41538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/tags?post=41538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}