{"id":50840,"date":"2020-01-20T21:21:00","date_gmt":"2020-01-20T20:21:00","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/que-es-el-flujo-interno-definicion\/"},"modified":"2020-01-20T21:21:00","modified_gmt":"2020-01-20T20:21:00","slug":"que-es-el-flujo-interno-definicion","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/","title":{"rendered":"\u00bfQu\u00e9 es el flujo interno? Definici\u00f3n"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\"><span>El flujo interno es un flujo para el cual el fluido est\u00e1 confinado por una superficie.\u00a0El conocimiento detallado del comportamiento de los reg\u00edmenes de flujo interno es importante en ingenier\u00eda.\u00a0Ingenieria termal<\/span><\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\"><\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<h2><span>Flujo interno<\/span><\/h2>\n<figure id=\"attachment_14394\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-14394\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Internal-Flow.png\"><img loading=\"lazy\" class=\"size-medium wp-image-14394 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Internal-Flow-300x269.png\" alt=\"Flujo interno\" width=\"300\" height=\"269\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Internal-Flow-300x269.png\" \/><\/a><figcaption id=\"caption-attachment-14394\" class=\"wp-caption-text\"><span>Fuente: White Frank M., Fluid Mechanics, McGraw-Hill Education, 7a edici\u00f3n, febrero de 2010, ISBN: 978-0077422417<\/span><\/figcaption><\/figure>\n<p><span>En la din\u00e1mica de fluidos, el flujo interno es un flujo para el cual el fluido est\u00e1\u00a0<\/span><strong><span>confinado por una superficie<\/span><\/strong><span>\u00a0.\u00a0El conocimiento detallado del comportamiento de los reg\u00edmenes de flujo interno es importante en ingenier\u00eda, ya que las tuber\u00edas circulares pueden soportar altas presiones y, por lo tanto, se utilizan para transportar l\u00edquidos.\u00a0Los conductos no circulares se utilizan para transportar gases a baja presi\u00f3n, como el aire en los sistemas de refrigeraci\u00f3n y calefacci\u00f3n.\u00a0La configuraci\u00f3n de flujo interno es una geometr\u00eda conveniente para calentar y enfriar fluidos utilizados en tecnolog\u00edas de conversi\u00f3n de energ\u00eda como\u00a0<\/span><a title=\"Planta de energ\u00eda nuclear\" href=\"https:\/\/www.nuclear-power.com\/nuclear-power-plant\/\"><span>las plantas de energ\u00eda nuclear<\/span><\/a><span>\u00a0.<\/span><\/p>\n<p><span>Para el r\u00e9gimen de flujo interno, una\u00a0<\/span><strong><span>regi\u00f3n de entrada<\/span><\/strong><span>\u00a0es t\u00edpica.\u00a0En esta regi\u00f3n, un flujo ascendente casi invisible se converge y entra al tubo.\u00a0Para caracterizar esta regi\u00f3n,\u00a0se introduce la\u00a0<\/span><strong><span>longitud de entrada hidrodin\u00e1mica<\/span><\/strong><span>\u00a0y es aproximadamente igual a:<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/hydrodynamic-entrance-length.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-14416 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/hydrodynamic-entrance-length.png\" alt=\"longitud de entrada hidrodin\u00e1mica\" width=\"365\" height=\"69\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/hydrodynamic-entrance-length.png\" \/><\/a><\/p>\n<p><span>La longitud m\u00e1xima de entrada hidrodin\u00e1mica, en\u00a0<\/span><strong><span>Re\u00a0<\/span><sub><span>D, crit<\/span><\/sub><span>\u00a0\u00a0= 2300<\/span><\/strong><span>\u00a0(\u00a0<\/span><strong><span>flujo laminar<\/span><\/strong><span>\u00a0), es L\u00a0<\/span><sub><span>e<\/span><\/sub><span>\u00a0= 138d, donde D es el di\u00e1metro de la tuber\u00eda.\u00a0Esta es la mayor longitud de desarrollo posible.\u00a0En el\u00a0<\/span><strong><span>flujo turbulento<\/span><\/strong><span>\u00a0, las capas l\u00edmite crecen m\u00e1s r\u00e1pido y L\u00a0<\/span><sub><span>e<\/span><\/sub><span>\u00a0\u00a0es relativamente m\u00e1s corto.\u00a0Para cualquier problema,\u00a0se debe\u00a0<strong>verificar\u00a0<\/strong><\/span><strong><span>L\u00a0<\/span><sub><span>e<\/span><\/sub><span>\u00a0\u00a0\/ D<\/span><\/strong><span>\u00a0para ver si L\u00a0<sub>e<\/sub>\u00a0\u00a0es insignificante en comparaci\u00f3n con la longitud de la tuber\u00eda.\u00a0A una distancia finita de la entrada, los efectos de entrada pueden descuidarse, porque las capas l\u00edmite se fusionan y el n\u00facleo invisible desaparece.\u00a0El flujo del tubo se\u00a0<strong>desarrolla completamente<\/strong>\u00a0.<\/span><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Di\u00e1metro hidr\u00e1ulico<\/span><\/h2>\n<p><span>Para simplificar a\u00fan m\u00e1s los c\u00e1lculos y\u00a0<\/span><strong><span>ampliar el rango de aplicaciones<\/span><\/strong><span>\u00a0,\u00a0se introduce el\u00a0<\/span><strong><span>di\u00e1metro hidr\u00e1ulico<\/span><\/strong><span>\u00a0:<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter-equation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-14418 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter-equation.png\" alt=\"Di\u00e1metro hidr\u00e1ulico - ecuaci\u00f3n\" width=\"99\" height=\"70\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter-equation.png\" \/><\/a><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter-non-circular-tubes.png\"><img loading=\"lazy\" class=\"alignright size-medium wp-image-14421 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter-non-circular-tubes-232x300.png\" alt=\"Di\u00e1metro hidr\u00e1ulico\" width=\"232\" height=\"300\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter-non-circular-tubes-232x300.png\" \/><\/a><strong><span>El di\u00e1metro hidr\u00e1ulico, D\u00a0<\/span><sub><span>h<\/span><\/sub><\/strong><span>\u00a0, es un t\u00e9rmino com\u00fanmente utilizado cuando se maneja el flujo en\u00a0<\/span><strong><span>tubos y canales no circulares<\/span><\/strong><span>\u00a0.\u00a0El di\u00e1metro hidr\u00e1ulico transforma los conductos no circulares en tuber\u00edas de\u00a0<\/span><strong><span>di\u00e1metro equivalente<\/span><\/strong><span>\u00a0.\u00a0Usando este t\u00e9rmino, uno puede calcular muchas cosas de la misma manera que para un tubo redondo.\u00a0En esta ecuaci\u00f3n, A es el\u00a0<\/span><strong><span>\u00e1rea de la secci\u00f3n transversal<\/span><\/strong><span>\u00a0, y P es el\u00a0<\/span><strong><span>per\u00edmetro humedecido<\/span><\/strong><span>\u00a0de la secci\u00f3n transversal.<\/span><\/p>\n<p><span>La mayor\u00eda de los flujos industriales, especialmente los de la ingenier\u00eda nuclear, son\u00a0<\/span><strong><span>turbulentos<\/span><\/strong><span>\u00a0.\u00a0Para el an\u00e1lisis de tuber\u00eda recta simple, suponiendo que el flujo unidireccional, los problemas de dise\u00f1o geom\u00e9trico y cinem\u00e1tico de la tuber\u00eda dependen del\u00a0<\/span><strong><span>diagrama Moody<\/span><\/strong><span>\u00a0y se pueden agrupar de la siguiente manera:<\/span><\/p>\n<ul>\n<li><span>Eval\u00fae las caracter\u00edsticas de bomba necesarias (caracter\u00edsticas de\u00a0<\/span><strong><span>QH<\/span><\/strong><span>\u00a0) en funci\u00f3n de la ca\u00edda de presi\u00f3n calculada \u0394p para transmitir un caudal m\u00e1ximo dado.<\/span><\/li>\n<li><span>Calcule una\u00a0<\/span><strong><span>ca\u00edda de presi\u00f3n<\/span><\/strong><span>\u00a0especificada\u00a0para la tuber\u00eda del di\u00e1metro D, de la longitud de la tuber\u00eda y el caudal dados.\u00a0Este problema requiere un procedimiento iterativo porque\u00a0no se conoce\u00a0el\u00a0<\/span><strong><span>n\u00famero de Reynolds<\/span><\/strong><span>\u00a0y, por lo tanto, el factor de fricci\u00f3n f.<\/span><\/li>\n<li><span>Calcule el\u00a0<\/span><strong><span>caudal Q<\/span><\/strong><span>\u00a0para una geometr\u00eda de tuber\u00eda dada (D, L,\u00a0<\/span><strong><span>\u03b5 \/ D<\/span><\/strong><span>\u00a0) y la ca\u00edda de presi\u00f3n, donde \u03b5 \/ D es la rugosidad relativa de la superficie.\u00a0Este problema requiere un procedimiento iterativo porque no se conoce el n\u00famero de Reynolds y, por lo tanto, el factor de fricci\u00f3n f.<\/span><\/li>\n<\/ul>\n<div class=\"su-spacer\"><\/div>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<h2><span>Ejemplo: n\u00famero de Reynolds para una tuber\u00eda primaria y un haz de combustible<\/span><\/h2>\n<p><a title=\"PWR - Reactor de agua a presi\u00f3n\" href=\"https:\/\/www.nuclear-power.com\/pwr-pressurized-water-reactor\/\"><strong><span>Los reactores de agua a presi\u00f3n<\/span><\/strong><\/a><span>\u00a0se enfr\u00edan y<\/span><a title=\"Moderador de neutrones\" href=\"https:\/\/www.nuclear-power.com\/neutron-moderator\/\"><span>\u00a0moderan<\/span><\/a><span>\u00a0con agua l\u00edquida a alta presi\u00f3n (p. Ej., 16MPa).\u00a0A esta presi\u00f3n, el agua hierve a aproximadamente 350 \u00b0 C (662 \u00b0 F).\u00a0La temperatura de entrada del agua es de aproximadamente 290 \u00b0 C (\u2374 ~ 720 kg \/ m<\/span><sup><span>\u00a03<\/span><\/sup><span>\u00a0).\u00a0El agua (refrigerante) se calienta en el n\u00facleo del reactor a aproximadamente 325 \u00b0 C (\u2374 ~ 654 kg \/ m<\/span><sup><span>\u00a03<\/span><\/sup><span>\u00a0) a medida que el agua fluye a trav\u00e9s<\/span><a title=\"N\u00facleo del reactor\" href=\"https:\/\/www.reactor-physics.com\/what-is-reactor-core-definition\/\"><span>\u00a0del n\u00facleo<\/span><\/a><span>\u00a0.<\/span><\/p>\n<figure id=\"attachment_14387\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-14387\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter.png\"><img loading=\"lazy\" class=\"wp-image-14387 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter.png\" alt=\"Di\u00e1metro hidr\u00e1ulico\" width=\"399\" height=\"293\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Hydraulic-Diameter.png\" \/><\/a><figcaption id=\"caption-attachment-14387\" class=\"wp-caption-text\"><span>El di\u00e1metro hidr\u00e1ulico del paquete de barras de combustible.<\/span><\/figcaption><\/figure>\n<p><span>El circuito primario de los PWR t\u00edpicos se divide en\u00a0<\/span><strong><span>4 circuitos independientes<\/span><\/strong><span>\u00a0(di\u00e1metro de tuber\u00eda ~ 700 mm), cada circuito comprende un\u00a0<\/span><a title=\"Generador de vapor\" href=\"https:\/\/www.nuclear-power.com\/steam-generator\/\"><strong><span>generador de vapor<\/span><\/strong><\/a><span>y una\u00a0<\/span><a title=\"Bomba de refrigerante del reactor\" href=\"https:\/\/www.nuclear-power.com\/reactor-coolant-pump\/\"><strong><span>bomba de refrigerante principal<\/span><\/strong><\/a><span>\u00a0.\u00a0Dentro del recipiente a presi\u00f3n del reactor (RPV), el refrigerante primero fluye hacia abajo fuera del n\u00facleo del reactor (a trav\u00e9s del\u00a0<\/span><strong><span>tubo de bajada<\/span><\/strong><span>\u00a0).\u00a0Desde el fondo del recipiente a presi\u00f3n, el flujo se invierte a trav\u00e9s del n\u00facleo, donde la temperatura del refrigerante aumenta a medida que pasa a trav\u00e9s de las barras de combustible y los conjuntos formados por ellas.<\/span><\/p>\n<p><span>Asumir:<\/span><\/p>\n<ul>\n<li><span>la velocidad de flujo de la tuber\u00eda primaria es constante e igual a 17 m \/ s,<\/span><\/li>\n<li><span>la velocidad del flujo central es constante e igual a 5 m \/ s,<\/span><\/li>\n<li><span>el\u00a0<\/span><strong><span>di\u00e1metro hidr\u00e1ulico del canal de combustible<\/span><\/strong><span>\u00a0,\u00a0<\/span><em><span>D\u00a0<\/span><\/em><em><sub><span>h<\/span><\/sub><\/em><span>\u00a0, es igual a 2 cm<\/span><\/li>\n<li><span>La viscosidad cinem\u00e1tica del agua a 290 \u00b0 C es igual a 0,12 x 10\u00a0<\/span><sup><span>-6<\/span><\/sup><span>\u00a0m\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0\/ s<\/span><\/li>\n<\/ul>\n<p><span>Ver tambi\u00e9n:\u00a0<\/span><a title=\"Ecuaci\u00f3n de continuidad\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-la-ecuacion-de-continuidad-definicion\/\"><span>Ejemplo:\u00a0<\/span><strong><span>velocidad de flujo a trav\u00e9s del n\u00facleo del reactor<\/span><\/strong><\/a><\/p>\n<p><span>Determinar<\/span><\/p>\n<ul>\n<li><span>el r\u00e9gimen de flujo y el n\u00famero de Reynolds dentro del\u00a0<\/span><strong><span>canal de combustible<\/span><\/strong><\/li>\n<li><span>El r\u00e9gimen de flujo y el n\u00famero de Reynolds dentro de la\u00a0<\/span><strong><span>tuber\u00eda primaria<\/span><\/strong><\/li>\n<\/ul>\n<p><span>El n\u00famero de Reynolds dentro de la tuber\u00eda primaria es igual a:<\/span><\/p>\n<p><strong><span>Re\u00a0<\/span><sub><span>D<\/span><\/sub><\/strong><span>\u00a0= 17 [m \/ s] x 0.7 [m] \/ 0.12 \u00d7 10\u00a0<\/span><sup><span>-6<\/span><\/sup><span>\u00a0[m\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0\/ s] =\u00a0<\/span><strong><span>99 000 000<\/span><\/strong><\/p>\n<p><span>Esto satisface completamente las\u00a0<\/span><strong><span>condiciones turbulentas<\/span><\/strong><span>\u00a0.<\/span><\/p>\n<p><span>El n\u00famero de Reynolds dentro del canal de combustible es igual a:<\/span><\/p>\n<p><strong><span>Re\u00a0<\/span><sub><span>DH<\/span><\/sub><\/strong><span>\u00a0= 5 [m \/ s] x 0.02 [m] \/ 0.12 \u00d7 10\u00a0<\/span><sup><span>-6<\/span><\/sup><span>\u00a0[m\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0\/ s] =\u00a0<\/span><strong><span>833 000<\/span><\/strong><\/p>\n<p><span>Esto tambi\u00e9n satisface completamente las\u00a0<\/span><strong><span>condiciones turbulentas.<\/span><\/strong><\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Este art\u00edculo se basa en la traducci\u00f3n autom\u00e1tica del art\u00edculo original en ingl\u00e9s. Para m\u00e1s informaci\u00f3n vea el art\u00edculo en ingl\u00e9s. Puedes ayudarnos. Si desea corregir la traducci\u00f3n, env\u00edela a: translations@nuclear-power.com o complete el formulario de traducci\u00f3n en l\u00ednea. Agradecemos su ayuda, actualizaremos la traducci\u00f3n lo antes posible. Gracias.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>El flujo interno es un flujo para el cual el fluido est\u00e1 confinado por una superficie.\u00a0El conocimiento detallado del comportamiento de los reg\u00edmenes de flujo interno es importante en ingenier\u00eda.\u00a0Ingenieria termal Flujo interno Fuente: White Frank M., Fluid Mechanics, McGraw-Hill Education, 7a edici\u00f3n, febrero de 2010, ISBN: 978-0077422417 En la din\u00e1mica de fluidos, el flujo &#8230; <a title=\"\u00bfQu\u00e9 es el flujo interno? Definici\u00f3n\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/\" aria-label=\"M\u00e1s en \u00bfQu\u00e9 es el flujo interno? Definici\u00f3n\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[16],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfQu\u00e9 es el flujo interno? Definici\u00f3n<\/title>\n<meta name=\"description\" content=\"El flujo interno es un flujo para el cual el fluido est\u00e1 confinado por una superficie. El conocimiento detallado del comportamiento de los reg\u00edmenes de flujo interno es importante en ingenier\u00eda. Ingenieria termal\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfQu\u00e9 es el flujo interno? Definici\u00f3n\" \/>\n<meta property=\"og:description\" content=\"El flujo interno es un flujo para el cual el fluido est\u00e1 confinado por una superficie. El conocimiento detallado del comportamiento de los reg\u00edmenes de flujo interno es importante en ingenier\u00eda. Ingenieria termal\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2020-01-20T20:21:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Internal-Flow-300x269.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"4 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Internal-Flow-300x269.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/\",\"name\":\"\\u00bfQu\\u00e9 es el flujo interno? Definici\\u00f3n\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/#primaryimage\"},\"datePublished\":\"2020-01-20T20:21:00+00:00\",\"dateModified\":\"2020-01-20T20:21:00+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"El flujo interno es un flujo para el cual el fluido est\\u00e1 confinado por una superficie. El conocimiento detallado del comportamiento de los reg\\u00edmenes de flujo interno es importante en ingenier\\u00eda. Ingenieria termal\",\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/es\/que-es-el-flujo-interno-definicion\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"es\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/50840"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/comments?post=50840"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/posts\/50840\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/media?parent=50840"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/categories?post=50840"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/es\/wp-json\/wp\/v2\/tags?post=50840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}