{"id":253843,"date":"2024-06-09T15:01:08","date_gmt":"2024-06-09T14:01:08","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/5-modeles-de-confort-thermique-en-architecture\/"},"modified":"2024-06-09T15:01:08","modified_gmt":"2024-06-09T14:01:08","slug":"5-modeles-de-confort-thermique-en-architecture","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/","title":{"rendered":"5 Mod\u00e8les de Confort Thermique en Architecture"},"content":{"rendered":"<p class=\"sidekick\">Mod\u00e8les de confort thermique en architecture : d\u00e9couvrez les principales th\u00e9ories pour \u00e9valuer et optimiser le bien-\u00eatre thermique des occupants dans les b\u00e2timents.<\/p>\n<p><img src=\"https:\/\/www.thermal-engineering.org\/wp-content\/uploads\/2024\/06\/5_modeles_de_confort_thermique_en_architecture.png\" alt=\"5 Mod\u00e8les de Confort Thermique en Architecture\" style=\"display: block; margin-left: auto; margin-right: auto;\"\/><\/p>\n<h2>5 Mod\u00e8les de Confort Thermique en Architecture<\/h2>\n<p>Le confort thermique est un aspect crucial dans la conception architecturale, car il impacte directement le bien-\u00eatre des occupants d&#8217;un b\u00e2timent. Divers mod\u00e8les th\u00e9oriques permettent de quantifier et d&#8217;optimiser ce confort. Voici un aper\u00e7u des cinq principaux mod\u00e8les utilis\u00e9s en architecture pour assurer un confort thermique optimal.<\/p>\n<h3>1. Mod\u00e8le de Fanger ou PMV\/PPD<\/h3>\n<p>Le <em>Predicted Mean Vote<\/em> (PMV) et le <em>Predicted Percentage of Dissatisfied<\/em> (PPD) sont des indices d\u00e9velopp\u00e9s par le professeur danois P.O. Fanger. Le mod\u00e8le de Fanger \u00e9value le confort thermique en tenant compte de six variables principales :<\/p>\n<ul>\n<li>Temp\u00e9rature de l&#8217;air<\/li>\n<li>Temp\u00e9rature radiante<\/li>\n<li>Humidit\u00e9 relative<\/li>\n<li>Vitesse de l&#8217;air<\/li>\n<li>Activit\u00e9 m\u00e9tabolique (niveau d&#8217;effort)<\/li>\n<li>Isolation vestimentaire<\/li>\n<\/ul>\n<p>Le PMV est une \u00e9chelle de confort thermique qui va de -3 (froid) \u00e0 +3 (chaud), o\u00f9 0 repr\u00e9sente le confort neutre. Le PPD calcule le pourcentage de personnes susceptibles d&#8217;\u00eatre insatisfaites du climat thermique.<\/p>\n<h3>2. Mod\u00e8le d&#8217;adaptation<\/h3>\n<p>Ce mod\u00e8le part de l&#8217;hypoth\u00e8se que les gens s&#8217;adaptent aux conditions thermiques changeantes dans leur environnement. Il repose principalement sur des enqu\u00eates de terrain et s&#8217;applique surtout aux b\u00e2timents naturellement ventil\u00e9s. Les occupants peuvent ajuster les fen\u00eatres, les stores, ou leur habillement pour atteindre un confort thermique.<\/p>\n<p>Dans ce mod\u00e8le, la temp\u00e9rature de confort pr\u00e9f\u00e9r\u00e9e est une fonction de la temp\u00e9rature ext\u00e9rieure moyenne r\u00e9cente, souvent exprim\u00e9e comme :<\/p>\n<p>T<sub>op<\/sub> = a \u00d7 T<sub>out<\/sub> + b<\/p>\n<p>o\u00f9 T<sub>op<\/sub> est la temp\u00e9rature de confort optimale, T<sub>out<\/sub> est la temp\u00e9rature ext\u00e9rieure, et a et b sont des constantes d\u00e9riv\u00e9es empiriquement.<\/p>\n<h3>3. Mod\u00e8le de confort thermique ASHRAE<\/h3>\n<p>L&#8217;American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) propose une norme (ASHRAE 55) qui d\u00e9finit des conditions acceptables pour le confort thermique. Ce mod\u00e8le prend en compte le PMV\/PPD mais ajoute des crit\u00e8res sp\u00e9cifiques pour diff\u00e9rents types d&#8217;espaces et d&#8217;usages, comme les bureaux, les habitations, et les \u00e9tablissements de sant\u00e9.<\/p>\n<p>La norme ASHRAE 55 fixe des plages de temp\u00e9rature et d&#8217;humidit\u00e9 pour diff\u00e9rentes saisons et activit\u00e9s, ce qui aide les ing\u00e9nieurs et architectes \u00e0 concevoir des b\u00e2timents confortables et efficaces.<\/p>\n<h3>4. Mod\u00e8le de confort thermique Gagge<\/h3>\n<p>Le mod\u00e8le de Gagge est bas\u00e9 sur le concept de &#8220;temp\u00e9rature op\u00e9rative&#8221;, une combinaison pond\u00e9r\u00e9e de la temp\u00e9rature de l&#8217;air et de la temp\u00e9rature moyenne radiante. Il inclut \u00e9galement des aspects thermor\u00e9gulateurs du corps humain, comme le transfert de chaleur par convection et radiation.<\/p>\n<p>Ce mod\u00e8le introduit l&#8217;indice de chaleur de Gagge (New Effective Temperature, ET<sub>new<\/sub>), qui permet d&#8217;\u00e9valuer l&#8217;impact des environnements chauds et humides sur le confort thermique.<\/p>\n<h3>5. Mod\u00e8le de l&#8217;\u00e9nergie humaine<\/h3>\n<p>Ce mod\u00e8le consid\u00e8re le bilan \u00e9nerg\u00e9tique du corps humain, qui inclut la production de chaleur m\u00e9tabolique, les pertes de chaleur par conduction, convection, radiation, et \u00e9vaporation. Le confort thermique est atteint lorsque la chaleur produite par le corps est \u00e9quilibr\u00e9e par les pertes de chaleur vers l&#8217;environnement.<\/p>\n<p>La structure de ce mod\u00e8le peut \u00eatre r\u00e9sum\u00e9e par l&#8217;\u00e9quation suivante :<\/p>\n<p>M &#8211; W = C + R + E + S<\/p>\n<p>o\u00f9 M est le m\u00e9tabolisme, W le travail externe, C la convection, R la radiation, E l&#8217;\u00e9vaporation et S le stockage de chaleur dans le corps.<\/p>\n<p>En r\u00e9sum\u00e9, ces mod\u00e8les offrent divers outils pour \u00e9valuer et optimiser le confort thermique dans les b\u00e2timents. Leur utilisation d\u00e9pend des objectifs et des sp\u00e9cificit\u00e9s de chaque projet architectural.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mod\u00e8les de confort thermique en architecture : d\u00e9couvrez les principales th\u00e9ories pour \u00e9valuer et optimiser le bien-\u00eatre thermique des occupants dans les b\u00e2timents.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[122],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>5 Mod\u00e8les de Confort Thermique en Architecture<\/title>\n<meta name=\"description\" content=\"Mod\u00e8les de confort thermique en architecture : d\u00e9couvrez les principales th\u00e9ories pour \u00e9valuer et optimiser le bien-\u00eatre thermique des occupants dans les b\u00e2timents.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"5 Mod\u00e8les de Confort Thermique en Architecture\" \/>\n<meta property=\"og:description\" content=\"Mod\u00e8les de confort thermique en architecture : d\u00e9couvrez les principales th\u00e9ories pour \u00e9valuer et optimiser le bien-\u00eatre thermique des occupants dans les b\u00e2timents.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2024-06-09T14:01:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.thermal-engineering.org\/wp-content\/uploads\/2024\/06\/5_modeles_de_confort_thermique_en_architecture.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture est.\">\n\t<meta name=\"twitter:data2\" content=\"3 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/www.thermal-engineering.org\/wp-content\/uploads\/2024\/06\/5_modeles_de_confort_thermique_en_architecture.png\",\"width\":1000,\"height\":1000,\"caption\":\"5 Mod\\u00e8les de Confort Thermique en Architecture\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/\",\"name\":\"5 Mod\\u00e8les de Confort Thermique en Architecture\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/#primaryimage\"},\"datePublished\":\"2024-06-09T14:01:08+00:00\",\"dateModified\":\"2024-06-09T14:01:08+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Mod\\u00e8les de confort thermique en architecture : d\\u00e9couvrez les principales th\\u00e9ories pour \\u00e9valuer et optimiser le bien-\\u00eatre thermique des occupants dans les b\\u00e2timents.\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/fr\/5-modeles-de-confort-thermique-en-architecture\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/253843"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/comments?post=253843"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/253843\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/media?parent=253843"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/categories?post=253843"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/tags?post=253843"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}