{"id":43042,"date":"2019-10-07T23:05:43","date_gmt":"2019-10-07T22:05:43","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/"},"modified":"2020-02-05T14:58:34","modified_gmt":"2020-02-05T13:58:34","slug":"quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/","title":{"rendered":"Qu&#8217;est-ce que l&#8217;\u00e9changeur de chaleur &#8211; Coefficient de transfert de chaleur &#8211; Facteur U &#8211; D\u00e9finition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">Un \u00e9changeur de chaleur implique g\u00e9n\u00e9ralement deux fluides en \u00e9coulement s\u00e9par\u00e9s par une paroi solide.\u00a0Le coefficient global de transfert de chaleur, U, est li\u00e9 \u00e0 la r\u00e9sistance thermique totale et d\u00e9pend de la g\u00e9om\u00e9trie du probl\u00e8me.\u00a0G\u00e9nie thermique<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Coefficient de transfert de chaleur global<\/h2>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/U-factor-Overall-Heat-Transfer-Coefficient-example.png\"><img loading=\"lazy\" class=\"alignright size-medium wp-image-20392 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/U-factor-Overall-Heat-Transfer-Coefficient-example-247x300.png\" alt=\"Facteur U - Coefficient de transfert de chaleur global\" width=\"247\" height=\"300\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/U-factor-Overall-Heat-Transfer-Coefficient-example-247x300.png\" \/><\/a>Un\u00a0<strong>\u00e9changeur de chaleur<\/strong>\u00a0implique g\u00e9n\u00e9ralement deux fluides en \u00e9coulement s\u00e9par\u00e9s par une paroi solide.\u00a0Un grand nombre des processus de transfert de chaleur rencontr\u00e9s dans l&#8217;industrie impliquent des syst\u00e8mes composites et m\u00eame une combinaison de\u00a0<a href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-conduction-thermique-conduction-thermique-definition\/\">conduction<\/a>\u00a0et de\u00a0<a href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-convection-transfert-de-chaleur-par-convection-definition\/\">convection<\/a>\u00a0.\u00a0La chaleur est d&#8217;abord transf\u00e9r\u00e9e du fluide chaud au mur par convection, \u00e0 travers le mur par conduction et de nouveau du fluide au froid par convection.<\/p>\n<p>Avec ces syst\u00e8mes composites, il est souvent commode de travailler avec un\u00a0<strong><a title=\"Coefficient de transfert de chaleur global - facteur U\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-coefficient-global-de-transfert-de-chaleur-facteur-u-definition\/\">coefficient global de transfert de chaleur<\/a>\u00a0,<\/strong>\u00a0connu comme un\u00a0<strong>facteur U<\/strong>\u00a0.\u00a0Le facteur U est d\u00e9fini par une expression analogue \u00e0\u00a0<strong>la loi de Newton sur le refroidissement<\/strong>\u00a0:<\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/overall-heat-transfer-coefficient-equation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-21046 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/overall-heat-transfer-coefficient-equation.png\" alt=\"coefficient global de transfert de chaleur - \u00e9quation\" width=\"359\" height=\"174\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/overall-heat-transfer-coefficient-equation.png\" \/><\/a><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/overall-heat-transfer-coefficient-table.png\"><img loading=\"lazy\" class=\"alignright size-full wp-image-21041 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/overall-heat-transfer-coefficient-table.png\" alt=\"coefficient global de transfert de chaleur - tableau\" width=\"413\" height=\"188\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/overall-heat-transfer-coefficient-table.png\" \/><\/a>Le\u00a0<strong>coefficient global de transfert de chaleur, U,<\/strong>\u00a0est li\u00e9 \u00e0 la\u00a0<a href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-resistance-thermique-resistivite-thermique-definition\/\">r\u00e9sistance thermique totale<\/a>\u00a0et d\u00e9pend de la g\u00e9om\u00e9trie du probl\u00e8me.\u00a0Par exemple,\u00a0<a href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-transfert-de-chaleur-definition\/\">le transfert de chaleur<\/a>\u00a0dans un\u00a0<a href=\"https:\/\/www.nuclear-power.com\/steam-generator\/\">g\u00e9n\u00e9rateur de vapeur<\/a>\u00a0implique la convection de la majeure partie du liquide de refroidissement du r\u00e9acteur vers la surface du tube interne du g\u00e9n\u00e9rateur de vapeur, la conduction \u00e0 travers la paroi du tube et la convection (\u00e9bullition) de la surface du tube externe vers le fluide du c\u00f4t\u00e9 secondaire.<\/p>\n<p>En cas de transfert de chaleur combin\u00e9 pour un \u00e9changeur de chaleur, il existe deux valeurs pour h.\u00a0Il existe un coefficient de transfert de chaleur par convection (h) pour le film de fluide \u00e0 l&#8217;int\u00e9rieur des tubes et un coefficient de transfert de chaleur par convection pour le film de fluide \u00e0 l&#8217;ext\u00e9rieur des tubes.\u00a0La\u00a0<a href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-conductivite-thermique-definition\/\">conductivit\u00e9 thermique<\/a> (k) et l&#8217;\u00e9paisseur (\u0394x) de la paroi du tube doivent \u00e9galement \u00eatre prises en compte.<\/p>\n<\/div>\n<\/div>\n<p>La surveillance en ligne des\u00a0<strong>\u00e9changeurs de chaleur<\/strong>\u00a0commerciaux\u00a0se fait en suivant le\u00a0<strong>coefficient de transfert de chaleur global\u00a0<\/strong>, car le coefficient de transfert de chaleur global a tendance \u00e0 diminuer avec le temps en raison de l&#8217;\u00a0<strong>encrassement\u00a0<\/strong>.\u00a0En calculant p\u00e9riodiquement le coefficient de transfert de chaleur global \u00e0 partir des d\u00e9bits et des temp\u00e9ratures de l&#8217;\u00e9changeur, l&#8217;op\u00e9rateur de l&#8217;\u00e9changeur de chaleur peut estimer la dur\u00e9e de vie des \u00e9changeurs de chaleur.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<h2><span>Exemple: calcul de l&#8217;\u00e9changeur de chaleur<\/span><\/h2>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/example-heat-exchanger-calculation-LMTD.png\"><img loading=\"lazy\" class=\"alignright size-medium wp-image-21042 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/example-heat-exchanger-calculation-LMTD-300x266.png\" alt=\"exemple - calcul d'\u00e9changeur de chaleur - LMTD\" width=\"300\" height=\"266\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/example-heat-exchanger-calculation-LMTD-300x266.png\" \/><\/a><span>Consid\u00e9rons un\u00a0<\/span><strong><span>\u00e9changeur de chaleur \u00e0 flux parall\u00e8le<\/span><\/strong><span>\u00a0, qui est utilis\u00e9 pour refroidir l&#8217;huile de 70 \u00b0 C \u00e0 40 \u00b0 C en utilisant de l&#8217;eau disponible \u00e0 30 \u00b0 C.\u00a0La temp\u00e9rature de sortie de l&#8217;eau est de 36 \u00b0 C.\u00a0Le d\u00e9bit d&#8217;huile est de 1 kg \/ s.\u00a0La chaleur sp\u00e9cifique de l&#8217;huile est de\u00a02,2 kJ \/ kg K. Le coefficient global de transfert de chaleur\u00a0<\/span><strong><span>U = 200 W \/ m\u00a0<\/span><sup><span>2<\/span><\/sup><span>\u00a0K<\/span><\/strong><span>\u00a0.<\/span><\/p>\n<p><span>Calculez la\u00a0<\/span><strong><span>diff\u00e9rence de temp\u00e9rature moyenne logarithmique<\/span><\/strong><span>\u00a0.\u00a0D\u00e9terminez la\u00a0<\/span><strong><span>surface<\/span><\/strong><span>\u00a0de cet \u00e9changeur de chaleur requise pour cette performance.<\/span><\/p>\n<ol>\n<li><strong><span>LMTD<\/span><\/strong><\/li>\n<\/ol>\n<p><span>La diff\u00e9rence de temp\u00e9rature moyenne logarithmique peut \u00eatre calcul\u00e9e simplement en utilisant sa d\u00e9finition:<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/LMTD-example.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-21050 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/LMTD-example.png\" alt=\"LMTD - exemple\" width=\"371\" height=\"76\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/LMTD-example.png\" \/><\/a><\/p>\n<ol start=\"2\">\n<li><span>Zone d&#8217;\u00e9changeur de chaleur<\/span><\/li>\n<\/ol>\n<p><span>Pour calculer la surface de cet \u00e9changeur de chaleur, nous devons calculer le d\u00e9bit de chaleur en utilisant le d\u00e9bit massique d&#8217;huile et de LMTD.<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Energy-Balance-Example.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-21049 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Energy-Balance-Example.png\" alt=\"Bilan \u00e9nerg\u00e9tique - Exemple\" width=\"412\" height=\"265\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Energy-Balance-Example.png\" \/><\/a><\/p>\n<p><span>La surface requise de cet \u00e9changeur de chaleur peut \u00eatre ensuite calcul\u00e9e directement \u00e0 l&#8217;aide de l&#8217;\u00e9quation g\u00e9n\u00e9rale de transfert de chaleur:<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/heat-exchanger-calculation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-21048 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/heat-exchanger-calculation.png\" alt=\"\u00e9changeur de chaleur - calcul\" width=\"512\" height=\"306\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/heat-exchanger-calculation.png\" \/><\/a><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\"><\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"su-spoiler-content su-clearfix\">\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Cet article est bas\u00e9 sur la traduction automatique de l&#8217;article original en anglais. Pour plus d&#8217;informations, voir l&#8217;article en anglais. Pouvez vous nous aider Si vous souhaitez corriger la traduction, envoyez-la \u00e0 l&#8217;adresse: translations@nuclear-power.com ou remplissez le formulaire de traduction en ligne. Nous appr\u00e9cions votre aide, nous mettrons \u00e0 jour la traduction le plus rapidement possible. Merci<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Un \u00e9changeur de chaleur implique g\u00e9n\u00e9ralement deux fluides en \u00e9coulement s\u00e9par\u00e9s par une paroi solide.\u00a0Le coefficient global de transfert de chaleur, U, est li\u00e9 \u00e0 la r\u00e9sistance thermique totale et d\u00e9pend de la g\u00e9om\u00e9trie du probl\u00e8me.\u00a0G\u00e9nie thermique Coefficient de transfert de chaleur global Un\u00a0\u00e9changeur de chaleur\u00a0implique g\u00e9n\u00e9ralement deux fluides en \u00e9coulement s\u00e9par\u00e9s par une paroi &#8230; <a title=\"Qu&#8217;est-ce que l&#8217;\u00e9changeur de chaleur &#8211; Coefficient de transfert de chaleur &#8211; Facteur U &#8211; D\u00e9finition\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/\" aria-label=\"En savoir plus sur Qu&#8217;est-ce que l&#8217;\u00e9changeur de chaleur &#8211; Coefficient de transfert de chaleur &#8211; Facteur U &#8211; D\u00e9finition\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[8],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Qu&#039;est-ce que l&#039;\u00e9changeur de chaleur - Coefficient de transfert de chaleur - Facteur U - D\u00e9finition<\/title>\n<meta name=\"description\" content=\"Un \u00e9changeur de chaleur implique g\u00e9n\u00e9ralement deux fluides en \u00e9coulement s\u00e9par\u00e9s par une paroi solide. Le coefficient global de transfert de chaleur, U, est li\u00e9 \u00e0 la r\u00e9sistance thermique totale et d\u00e9pend de la g\u00e9om\u00e9trie du probl\u00e8me. G\u00e9nie thermique\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Qu&#039;est-ce que l&#039;\u00e9changeur de chaleur - Coefficient de transfert de chaleur - Facteur U - D\u00e9finition\" \/>\n<meta property=\"og:description\" content=\"Un \u00e9changeur de chaleur implique g\u00e9n\u00e9ralement deux fluides en \u00e9coulement s\u00e9par\u00e9s par une paroi solide. Le coefficient global de transfert de chaleur, U, est li\u00e9 \u00e0 la r\u00e9sistance thermique totale et d\u00e9pend de la g\u00e9om\u00e9trie du probl\u00e8me. G\u00e9nie thermique\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-07T22:05:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-05T13:58:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/U-factor-Overall-Heat-Transfer-Coefficient-example-247x300.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture est.\">\n\t<meta name=\"twitter:data2\" content=\"3 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/U-factor-Overall-Heat-Transfer-Coefficient-example-247x300.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/\",\"name\":\"Qu'est-ce que l'\\u00e9changeur de chaleur - Coefficient de transfert de chaleur - Facteur U - D\\u00e9finition\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/#primaryimage\"},\"datePublished\":\"2019-10-07T22:05:43+00:00\",\"dateModified\":\"2020-02-05T13:58:34+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Un \\u00e9changeur de chaleur implique g\\u00e9n\\u00e9ralement deux fluides en \\u00e9coulement s\\u00e9par\\u00e9s par une paroi solide. Le coefficient global de transfert de chaleur, U, est li\\u00e9 \\u00e0 la r\\u00e9sistance thermique totale et d\\u00e9pend de la g\\u00e9om\\u00e9trie du probl\\u00e8me. G\\u00e9nie thermique\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-lechangeur-de-chaleur-coefficient-de-transfert-de-chaleur-facteur-u-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/43042"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/comments?post=43042"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/43042\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/media?parent=43042"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/categories?post=43042"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/tags?post=43042"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}