{"id":43066,"date":"2019-10-08T00:54:11","date_gmt":"2019-10-07T23:54:11","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/quest-ce-que-la-methode-defficacite-ntu-definition\/"},"modified":"2020-02-06T08:29:39","modified_gmt":"2020-02-06T07:29:39","slug":"quest-ce-que-la-methode-defficacite-ntu-definition","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/","title":{"rendered":"Qu&#8217;est-ce que la m\u00e9thode d&#8217;efficacit\u00e9 NTU &#8211; D\u00e9finition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">Dans la m\u00e9thode NTU (m\u00e9thode du nombre d&#8217;unit\u00e9s de transfert), l&#8217;efficacit\u00e9 est le rapport entre le taux de transfert de chaleur r\u00e9el et le taux de transfert de chaleur maximal possible.\u00a0G\u00e9nie thermique<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>M\u00e9thode d&#8217;efficacit\u00e9 NTU<\/h2>\n<p>La\u00a0m\u00e9thode\u00a0<a title=\"Diff\u00e9rence de temp\u00e9rature moyenne logarithmique - LMTD\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/heat-transfer\/heat-exchangers\/logarithmic-mean-temperature-difference-lmtd\/\"><strong>logarithmique diff\u00e9rentielle de temp\u00e9rature<\/strong><\/a>\u00a0(LMTD) d\u00e9crite dans la section pr\u00e9c\u00e9dente est facile \u00e0 utiliser dans l\u2019analyse des \u00e9changeurs thermiques lorsque les temp\u00e9ratures d\u2019entr\u00e9e et de sortie des fluides chauds et froids sont connues ou peuvent \u00eatre d\u00e9termin\u00e9es \u00e0 partir d\u2019un bilan \u00e9nerg\u00e9tique.\u00a0Par cons\u00e9quent, la m\u00e9thode LMTD est tr\u00e8s appropri\u00e9e pour d\u00e9terminer la taille et les performances d&#8217;un \u00e9changeur de chaleur.<\/p>\n<p>Lorsque la connaissance directe de la DTMT n&#8217;est pas disponible et que la m\u00e9thode NTU (m\u00e9thode du\u00a0<strong>nombre d&#8217;unit\u00e9s de transfert<\/strong>\u00a0) peut \u00eatre utilis\u00e9e.\u00a0Cette m\u00e9thode est bas\u00e9e sur un param\u00e8tre sans dimension appel\u00e9 efficacit\u00e9 du transfert de chaleur, d\u00e9fini comme suit:<\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-21051 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\" alt=\"M\u00e9thode d'efficacit\u00e9 NTU - \u00e9quation\" width=\"368\" height=\"53\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\" \/><\/a><\/p>\n<p>Comme on peut le constater, l&#8217;\u00a0<em>efficacit\u00e9<\/em>\u00a0est le rapport entre le taux de transfert de chaleur r\u00e9el et le taux de transfert de chaleur maximal possible.\u00a0Pour d\u00e9finir l&#8217;efficacit\u00e9 d&#8217;un \u00e9changeur de chaleur, nous devons d&#8217;abord d\u00e9terminer le taux de transfert de chaleur maximal possible, q\u00a0<sub>max<\/sub>\u00a0, pour l&#8217;\u00e9changeur de chaleur.<\/p>\n<p><strong>M\u00e9thode d&#8217;efficacit\u00e9 NTU<\/strong><\/p>\n<p>Lectures compl\u00e9mentaires:<\/p>\n<ol>\n<li>Principes de base du transfert de chaleur et de masse, 7e \u00e9dition.\u00a0Theodore L. Bergman, Adrienne S. Lavine et Frank P. Incropera.\u00a0John Wiley &amp; Sons, Incorporated, 2011. ISBN: 9781118137253.<\/li>\n<li>Transfert de chaleur et de masse.\u00a0Yunus A. Cengel.\u00a0McGraw-Hill Education, 2011. ISBN: 9780071077866.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-accordion\">\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-arrow\" data-anchor=\"References\">\n<div class=\"su-spoiler-content su-clearfix\"><\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Cet article est bas\u00e9 sur la traduction automatique de l&#8217;article original en anglais. Pour plus d&#8217;informations, voir l&#8217;article en anglais. Pouvez vous nous aider Si vous souhaitez corriger la traduction, envoyez-la \u00e0 l&#8217;adresse: translations@nuclear-power.com ou remplissez le formulaire de traduction en ligne. Nous appr\u00e9cions votre aide, nous mettrons \u00e0 jour la traduction le plus rapidement possible. Merci<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Dans la m\u00e9thode NTU (m\u00e9thode du nombre d&#8217;unit\u00e9s de transfert), l&#8217;efficacit\u00e9 est le rapport entre le taux de transfert de chaleur r\u00e9el et le taux de transfert de chaleur maximal possible.\u00a0G\u00e9nie thermique M\u00e9thode d&#8217;efficacit\u00e9 NTU La\u00a0m\u00e9thode\u00a0logarithmique diff\u00e9rentielle de temp\u00e9rature\u00a0(LMTD) d\u00e9crite dans la section pr\u00e9c\u00e9dente est facile \u00e0 utiliser dans l\u2019analyse des \u00e9changeurs thermiques lorsque les &#8230; <a title=\"Qu&#8217;est-ce que la m\u00e9thode d&#8217;efficacit\u00e9 NTU &#8211; D\u00e9finition\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/\" aria-label=\"En savoir plus sur Qu&#8217;est-ce que la m\u00e9thode d&#8217;efficacit\u00e9 NTU &#8211; D\u00e9finition\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[8],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Qu&#039;est-ce que la m\u00e9thode d&#039;efficacit\u00e9 NTU - D\u00e9finition<\/title>\n<meta name=\"description\" content=\"Dans la m\u00e9thode NTU (m\u00e9thode du nombre d&#039;unit\u00e9s de transfert), l&#039;efficacit\u00e9 est le rapport entre le taux de transfert de chaleur r\u00e9el et le taux de transfert de chaleur maximal possible. G\u00e9nie thermique\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Qu&#039;est-ce que la m\u00e9thode d&#039;efficacit\u00e9 NTU - D\u00e9finition\" \/>\n<meta property=\"og:description\" content=\"Dans la m\u00e9thode NTU (m\u00e9thode du nombre d&#039;unit\u00e9s de transfert), l&#039;efficacit\u00e9 est le rapport entre le taux de transfert de chaleur r\u00e9el et le taux de transfert de chaleur maximal possible. G\u00e9nie thermique\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-07T23:54:11+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-06T07:29:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture est.\">\n\t<meta name=\"twitter:data2\" content=\"1 minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/NTU-Effectiveness-Method-equation.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/\",\"name\":\"Qu'est-ce que la m\\u00e9thode d'efficacit\\u00e9 NTU - D\\u00e9finition\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/#primaryimage\"},\"datePublished\":\"2019-10-07T23:54:11+00:00\",\"dateModified\":\"2020-02-06T07:29:39+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"Dans la m\\u00e9thode NTU (m\\u00e9thode du nombre d'unit\\u00e9s de transfert), l'efficacit\\u00e9 est le rapport entre le taux de transfert de chaleur r\\u00e9el et le taux de transfert de chaleur maximal possible. G\\u00e9nie thermique\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-methode-defficacite-ntu-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/43066"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/comments?post=43066"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/43066\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/media?parent=43066"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/categories?post=43066"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/tags?post=43066"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}