{"id":43274,"date":"2019-10-08T18:35:04","date_gmt":"2019-10-08T17:35:04","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/quest-ce-que-la-circulation-naturelle-definition\/"},"modified":"2020-02-17T08:31:04","modified_gmt":"2020-02-17T07:31:04","slug":"quest-ce-que-la-circulation-naturelle-definition","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/","title":{"rendered":"Qu&#8217;est-ce que la circulation naturelle &#8211; D\u00e9finition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">La circulation naturelle est la circulation de fluide dans les syst\u00e8mes de canalisation ou les piscines ouvertes due aux changements de densit\u00e9 caus\u00e9s par les diff\u00e9rences de temp\u00e9rature.\u00a0G\u00e9nie thermique<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Circulation naturelle<\/h2>\n<figure id=\"attachment_20639\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-20639\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema.png\"><img loading=\"lazy\" class=\"size-medium wp-image-20639 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema-300x219.png\" alt=\"Circulation naturelle - sch\u00e9ma\" width=\"300\" height=\"219\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema-300x219.png\" \/><\/a><figcaption id=\"caption-attachment-20639\" class=\"wp-caption-text\">Circulation naturelle en boucle ferm\u00e9e<\/figcaption><\/figure>\n<p><strong>La circulation naturelle<\/strong>\u00a0est la circulation de fluide dans\u00a0<strong>les syst\u00e8mes de canalisation<\/strong>\u00a0ou\u00a0<strong>les piscines ouvertes<\/strong>\u00a0due aux\u00a0<strong>changements de densit\u00e9<\/strong>\u00a0caus\u00e9s par les diff\u00e9rences de temp\u00e9rature.\u00a0<strong>La circulation naturelle<\/strong>\u00a0ne n\u00e9cessite aucun dispositif m\u00e9canique pour maintenir le d\u00e9bit.<\/p>\n<p>Ce ph\u00e9nom\u00e8ne a une nature similaire \u00e0 la convection naturelle, mais dans ce cas, le coefficient de transfert de chaleur n\u2019est pas un objet d\u2019\u00e9tude.\u00a0Dans ce cas, le\u00a0<strong>flux<\/strong>\u00a0massif\u00a0<strong>dans la boucle<\/strong>\u00a0fait l&#8217;objet d&#8217;une \u00e9tude.\u00a0Ce ph\u00e9nom\u00e8ne est plut\u00f4t un\u00a0<strong>probl\u00e8me hydraulique<\/strong>\u00a0qu\u2019un\u00a0<strong>probl\u00e8me<\/strong> de transfert de chaleur, bien qu\u2019il en r\u00e9sulte que la circulation naturelle \u00e9limine la chaleur de la source et la transporte vers le puits de chaleur et qu\u2019elle rev\u00eat la plus haute importance pour la s\u00e9curit\u00e9 des r\u00e9acteurs.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<h2><span>Conditions requises pour la circulation naturelle<\/span><\/h2>\n<p><span>De m\u00eame que pour\u00a0<\/span><strong><span>la convection naturelle<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>la circulation naturelle<\/span><\/strong><span>\u00a0ne fonctionne essentiellement pas sur l&#8217;orbite de la Terre.\u00a0La circulation naturelle se produit dans une boucle uniquement dans des conditions sp\u00e9cifiques.\u00a0M\u00eame apr\u00e8s le d\u00e9but de la circulation naturelle, l&#8217;\u00e9limination de l&#8217;une de ces conditions entra\u00eenera l&#8217;\u00a0<\/span><strong><span>arr\u00eat de la circulation naturelle<\/span><\/strong><span>\u00a0.\u00a0Les conditions de circulation naturelle sont les suivantes:<\/span><\/p>\n<ul>\n<li><strong><span>Pr\u00e9sence d&#8217;une bonne acc\u00e9l\u00e9ration.\u00a0<\/span><\/strong><span>La circulation naturelle ne peut se produire que dans un champ gravitationnel ou en pr\u00e9sence d&#8217;une autre bonne acc\u00e9l\u00e9ration, telle que l&#8217;acc\u00e9l\u00e9ration, la force centrifuge.<\/span><\/li>\n<li><strong><span>Pr\u00e9sence de source de chaleur et dissipateur de chaleur<\/span><\/strong><span>\u00a0.\u00a0Une source de chaleur et un dissipateur de chaleur sont n\u00e9cessaires, car\u00a0<\/span><strong><span>la circulation naturelle<\/span><\/strong><span>est g\u00e9n\u00e9r\u00e9 par une diff\u00e9rence de densit\u00e9 dans le fluide due \u00e0 une diff\u00e9rence de temp\u00e9rature.\u00a0Le fluide entrant dans une source de chaleur re\u00e7oit de la chaleur et par dilatation thermique devient moins dense et monte.\u00a0La dilatation thermique du fluide joue un r\u00f4le crucial.\u00a0Le processus dans un chant de chaleur est oppos\u00e9, le chant de chaleur re\u00e7oit de la chaleur et le fluide devient plus dense.\u00a0La diff\u00e9rence de densit\u00e9 est la force motrice du flux de circulation naturel.\u00a0La diff\u00e9rence de temp\u00e9rature doit \u00eatre maintenue pour que la circulation naturelle se poursuive.\u00a0L&#8217;addition de chaleur par une source de chaleur doit exister dans la zone de temp\u00e9rature \u00e9lev\u00e9e.\u00a0L&#8217;\u00e9vacuation continue de la chaleur par un dissipateur thermique doit exister dans la zone \u00e0 basse temp\u00e9rature.\u00a0Sinon, les temp\u00e9ratures finiraient par s&#8217;\u00e9galiser et aucune autre circulation ne se produirait.<\/span><\/li>\n<li><strong><span>G\u00e9om\u00e9trie appropri\u00e9e<\/span><\/strong><span>.\u00a0La pr\u00e9sence et l&#8217;ampleur de la circulation naturelle d\u00e9pendent \u00e9galement de la g\u00e9om\u00e9trie du probl\u00e8me.\u00a0La pr\u00e9sence d&#8217;un gradient de densit\u00e9 de fluide dans un champ gravitationnel ne garantit pas l&#8217;existence de courants de convection naturels.\u00a0La circulation naturelle dans une boucle ferm\u00e9e remplie de fluide est \u00e9tablie en pla\u00e7ant un dissipateur de chaleur dans la boucle \u00e0 une altitude sup\u00e9rieure \u00e0 la source de chaleur.\u00a0Le fluide caloporteur retire la chaleur de la source et la transporte vers l&#8217;\u00e9vier.\u00a0L&#8217;\u00e9coulement peut \u00eatre monophas\u00e9 ou biphas\u00e9 dans lequel la vapeur s&#8217;\u00e9coule le long du liquide.\u00a0La diff\u00e9rence de temp\u00e9rature doit \u00eatre maintenue pour que la circulation naturelle se poursuive.\u00a0L&#8217;addition de chaleur par une source de chaleur doit exister dans la zone de temp\u00e9rature \u00e9lev\u00e9e.\u00a0L&#8217;\u00e9vacuation continue de la chaleur par un dissipateur thermique doit exister dans la zone \u00e0 basse temp\u00e9rature.\u00a0Sinon, les temp\u00e9ratures finiraient par s&#8217;\u00e9galiser,\u00a0et aucune autre circulation ne se produirait.\u00a0Il est possible d&#8217;avoir une circulation naturelle dans un \u00e9coulement diphasique, mais il est g\u00e9n\u00e9ralement plus difficile de maintenir l&#8217;\u00e9coulement.<\/span><\/li>\n<li><strong><span>Fluides en contact<\/span><\/strong><span>\u00a0.\u00a0Les deux zones doivent \u00eatre en contact pour que l&#8217;\u00e9coulement entre les zones soit possible.\u00a0Si le chemin d&#8217;\u00e9coulement est obstru\u00e9 ou bloqu\u00e9, la circulation naturelle ne peut pas se produire.<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Circulation naturelle &#8211; D\u00e9bit<\/span><\/h2>\n<p><strong><span>Le<\/span><\/strong><span>\u00a0d\u00e9bit de\u00a0<strong>circulation naturelle<\/strong>\u00a0dans la boucle, en r\u00e9gime permanent, est d\u00e9termin\u00e9 \u00e0 partir de l&#8217;\u00a0<\/span><strong><span>\u00e9quilibre<\/span><\/strong><span>\u00a0entre les\u00a0<strong>forces\u00a0<\/strong><\/span><strong><span>motrices<\/span><\/strong><span>\u00a0et\u00a0<\/span><strong><span>r\u00e9sistantes<\/span><\/strong><span>\u00a0.\u00a0La force motrice r\u00e9sulte de la diff\u00e9rence de densit\u00e9 entre la jambe chaude et la jambe froide de la boucle.\u00a0La t\u00eate n\u00e9cessaire pour compenser les pertes de charge est cr\u00e9\u00e9e par les gradients de densit\u00e9 et les changements d&#8217;\u00e9l\u00e9vation.<\/span><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>T\u00eate d&#8217;entra\u00eenement thermique<\/span><\/h2>\n<p><strong><span>La t\u00eate d&#8217;entra\u00eenement thermique<\/span><\/strong><span>\u00a0est la force qui provoque\u00a0<\/span><strong><span>la circulation naturelle<\/span><\/strong><span>\u00a0.\u00a0Elle est caus\u00e9e par la diff\u00e9rence de\u00a0<\/span><a title=\"Qu'est-ce que la densit\u00e9 - Physique\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/thermodynamics\/thermodynamic-properties\/what-is-density-physics\/\"><span>densit\u00e9<\/span><\/a><span>\u00a0entre deux corps ou zones de fluide.\u00a0Consid\u00e9rons deux volumes \u00e9gaux du m\u00eame type de fluide.\u00a0Si les deux volumes ne sont pas \u00e0 la m\u00eame\u00a0<\/span><a title=\"Qu'est-ce que la temp\u00e9rature - Physique\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-temperature-physique-definition\/\"><span>temp\u00e9rature<\/span><\/a><span>\u00a0, alors le\u00a0<\/span><a title=\"Qu'est-ce que le volume - Physique\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/thermodynamics\/thermodynamic-properties\/what-is-volume-physics\/\"><span>volume<\/span><\/a><span>\u00a0avec la temp\u00e9rature la plus \u00e9lev\u00e9e aura \u00e9galement une densit\u00e9 plus faible et donc une masse moindre.\u00a0Il est connu que la densit\u00e9 des gaz et des liquides d\u00e9pend de la temp\u00e9rature, diminuant g\u00e9n\u00e9ralement (en raison de l&#8217;expansion du fluide) avec l&#8217;augmentation de la temp\u00e9rature.\u00a0\u00c9tant donn\u00e9 que le volume \u00e0 la temp\u00e9rature plus \u00e9lev\u00e9e aura une\u00a0<a title=\"Qu'est-ce que la masse\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/thermodynamics\/thermodynamic-properties\/what-is-mass-and-weight\/what-is-mass\/\">masse<\/a>\u00a0inf\u00e9rieure<\/span><span>, il aura \u00e9galement moins de force exerc\u00e9e sur lui par gravit\u00e9.\u00a0Cette diff\u00e9rence de force de gravit\u00e9 exerc\u00e9e sur le fluide aura tendance \u00e0 faire monter le fluide plus chaud et \u00e0 couler le fluide plus froid.\u00a0<\/span><strong><span>La t\u00eate d&#8217;entra\u00eenement thermique<\/span><\/strong><span>\u00a0peut \u00eatre calcul\u00e9e simplement en utilisant la diff\u00e9rence de pressions hydrostatiques:<\/span><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/thermal-driving-head-equation.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-20658 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/thermal-driving-head-equation.png\" alt=\"t\u00eate d'entra\u00eenement thermique - \u00e9quation\" width=\"377\" height=\"58\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/thermal-driving-head-equation.png\" \/><\/a><\/p>\n<p><span>Comme on peut le voir, plus la diff\u00e9rence de temp\u00e9rature entre les zones chaudes et froides de fluide est grande, plus la\u00a0<\/span><strong><span>t\u00eate d&#8217;entra\u00eenement thermique<\/span><\/strong><span> et le d\u00e9bit r\u00e9sultant sont importants.<\/span><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Force de r\u00e9sistance hydraulique<\/span><\/h2>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/PLC-Pressure-loss-coefficient-equations.png\"><img loading=\"lazy\" class=\"alignright size-full wp-image-20526 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/PLC-Pressure-loss-coefficient-equations.png\" alt=\"PLC - Coefficient de perte de pression - \u00e9quations\" width=\"339\" height=\"375\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/PLC-Pressure-loss-coefficient-equations.png\" \/><\/a><span>Comme il a \u00e9t\u00e9 \u00e9crit,\u00a0<\/span><strong><span>le d\u00e9bit de circulation naturel<\/span><\/strong><span>\u00a0, V, dans la boucle, dans un \u00e9tat stationnaire est d\u00e9termin\u00e9 \u00e0 partir de l&#8217;\u00e9quilibre entre la t\u00eate d&#8217;entra\u00eenement et les forces de r\u00e9sistance.\u00a0Comme la friction des tuyaux, les\u00a0<\/span><strong><span>pertes de charge globales<\/span><\/strong><span>\u00a0sont\u00a0<\/span><strong><span>proportionnelles au carr\u00e9 du d\u00e9bit<\/span><\/strong><span>\u00a0et peuvent donc \u00eatre facilement int\u00e9gr\u00e9es dans l&#8217;\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/major-head-loss-friction-loss\/darcy-weisbach-equation\/\"><strong><span>\u00e9quation de Darcy-Weisbach<\/span><\/strong><\/a><span>\u00a0.\u00a0Les ing\u00e9nieurs utilisent souvent le\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/bernoullis-equation-bernoullis-principle\/head-loss\/pressure-loss-coefficient-plc\/\"><strong><span>coefficient de perte de pression<\/span><\/strong><\/a><span>\u00a0,\u00a0<\/span><strong><span>PLC<\/span><\/strong><span>\u00a0.\u00a0Il est not\u00e9 K ou\u00a0<\/span><strong><span>\u03be<\/span><\/strong><span>\u00a0(prononc\u00e9 \u00abxi\u00bb).\u00a0Ce coefficient caract\u00e9rise\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/bernoullis-equation-bernoullis-principle\/head-loss\/\"><span>la perte de pression<\/span><\/a><span>d&#8217;un certain syst\u00e8me hydraulique ou d&#8217;une partie d&#8217;un syst\u00e8me hydraulique.\u00a0Il peut \u00eatre facilement mesur\u00e9 dans les boucles hydrauliques.\u00a0Le coefficient de perte de charge peut \u00eatre d\u00e9fini ou mesur\u00e9 pour les deux tuyaux droits et en particulier pour\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/minor-head-loss-local-losses\/\"><strong><span>les pertes locales (mineures)<\/span><\/strong><\/a><span>\u00a0.\u00a0Comme le\u00a0<\/span><a title=\"Facteur de friction Darcy\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-facteur-de-friction-de-darcy-definition\/\"><span>facteur de friction de Darcy<\/span><\/a><span>\u00a0est fonction de la vitesse (en nombre de Reynolds), le calcul du coefficient de perte de pression est un processus it\u00e9ratif.<\/span><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Circulation naturelle dans l&#8217;ing\u00e9nierie des r\u00e9acteurs<\/span><\/h2>\n<figure id=\"attachment_20639\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-20639\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema.png\"><img loading=\"lazy\" class=\"size-medium wp-image-20639 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema-300x219.png\" alt=\"Circulation naturelle - sch\u00e9ma\" width=\"300\" height=\"219\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema-300x219.png\" \/><\/a><figcaption id=\"caption-attachment-20639\" class=\"wp-caption-text\"><span>Circulation naturelle en boucle ferm\u00e9e<\/span><\/figcaption><\/figure>\n<p><span>Dans l&#8217;\u00a0<\/span><a title=\"Ing\u00e9nierie nucl\u00e9aire\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/\"><span>ing\u00e9nierie des r\u00e9acteurs<\/span><\/a><span>\u00a0,\u00a0<\/span><strong><span>la circulation naturelle<\/span><\/strong><span>\u00a0est un ph\u00e9nom\u00e8ne tr\u00e8s souhait\u00e9, car il est capable d&#8217;assurer le\u00a0<\/span><a title=\"Refroidissement du r\u00e9acteur\" href=\"https:\/\/www.nuclear-power.com\/nuclear-power\/reactor-physics\/reactor-operation\/reactor-cooling\/\"><strong><span>refroidissement du c\u0153ur du r\u00e9acteur<\/span><\/strong><\/a><span>\u00a0apr\u00e8s la perte des\u00a0<\/span><a href=\"https:\/\/www.nuclear-power.com\/reactor-coolant-pump\/\"><strong><span>RCP<\/span><\/strong><\/a><span>\u00a0(par exemple apr\u00e8s la perte de puissance hors site &#8211; LOOP).\u00a0Dans les REP, la conception de l&#8217;usine fournit une\u00a0<\/span><strong><span>diff\u00e9rence d&#8217;\u00e9l\u00e9vation<\/span><\/strong><span>\u00a0,\u00a0<\/span><strong><span>h<\/span><\/strong><span>\u00a0, d&#8217;environ\u00a0<\/span><strong><span>12 m\u00e8tres<\/span><\/strong><span>\u00a0entre la ligne m\u00e9diane du\u00a0<\/span><a title=\"G\u00e9n\u00e9rateur de vapeur\" href=\"https:\/\/www.nuclear-power.com\/steam-generator\/\"><span>g\u00e9n\u00e9rateur de vapeur<\/span><\/a><span>\u00a0et la ligne m\u00e9diane du\u00a0<\/span><a title=\"Noyau du r\u00e9acteur\" href=\"https:\/\/www.reactor-physics.com\/what-is-reactor-core-definition\/\"><span>c\u0153ur<\/span><\/a><span>\u00a0du\u00a0<a title=\"Noyau du r\u00e9acteur\" href=\"https:\/\/www.reactor-physics.com\/what-is-reactor-core-definition\/\">r\u00e9acteur<\/a>\u00a0.\u00a0La disposition du syst\u00e8me doit assurer une capacit\u00e9 de circulation naturelle apr\u00e8s une perte de d\u00e9bit pour permettre le refroidissement sans surchauffer le c\u0153ur.\u00a0De plus, la tuyauterie d&#8217;interconnexion de la\u00a0<a title=\"R\u00e9cipient sous pression du r\u00e9acteur\" href=\"https:\/\/www.nuclear-power.com\/nuclear-power-plant\/nuclear-reactor\/reactor-pressure-vessel\/\">cuve sous pression<\/a>\u00a0du\u00a0<\/span><a title=\"R\u00e9cipient sous pression du r\u00e9acteur\" href=\"https:\/\/www.nuclear-power.com\/nuclear-power-plant\/nuclear-reactor\/reactor-pressure-vessel\/\"><span>r\u00e9acteur<\/span><\/a><span>Les g\u00e9n\u00e9rateurs de vapeur doivent \u00eatre intacts, exempts d&#8217;obstacles tels que des gaz non condensables (par exemple des poches de vapeur).\u00a0De cette fa\u00e7on, la circulation naturelle garantira que le fluide continuera \u00e0 couler tant que le r\u00e9acteur sera plus chaud que le dissipateur de chaleur, m\u00eame lorsque l&#8217;alimentation des pompes ne pourra pas \u00eatre assur\u00e9e.<\/span><\/p>\n<p><a title=\"Pompe de refroidissement du r\u00e9acteur\" href=\"https:\/\/www.nuclear-power.com\/reactor-coolant-pump\/\"><span>Les RCP<\/span><\/a><span>\u00a0ne sont g\u00e9n\u00e9ralement pas des \u00absyst\u00e8mes de s\u00e9curit\u00e9\u00bb, tels que d\u00e9finis.\u00a0Apr\u00e8s la perte de RCP (par exemple apr\u00e8s une perte de puissance hors site &#8211; LOOP), le r\u00e9acteur doit \u00eatre arr\u00eat\u00e9 imm\u00e9diatement, car les RCP ralentissent lentement jusqu&#8217;\u00e0 un d\u00e9bit nul.\u00a0Une \u00e9vacuation suffisante et s\u00fbre de la chaleur r\u00e9siduelle est alors assur\u00e9e par un\u00a0flux de\u00a0<\/span><strong><span>circulation naturelle \u00e0<\/span><\/strong><span>\u00a0travers le r\u00e9acteur.\u00a0Sans \u00e9coulement forc\u00e9, le liquide de refroidissement dans le c\u0153ur commence \u00e0 chauffer.\u00a0L&#8217;augmentation de la temp\u00e9rature du liquide de refroidissement entra\u00eene une r\u00e9duction de la densit\u00e9 du liquide de refroidissement, qui \u00e0 son tour d\u00e9place le liquide de refroidissement dans le g\u00e9n\u00e9rateur de vapeur.\u00a0Il faut noter que la circulation naturelle n&#8217;est pas suffisante pour \u00e9vacuer la chaleur g\u00e9n\u00e9r\u00e9e lorsque le r\u00e9acteur est \u00e0 puissance.<\/span><\/p>\n<p><span>Les conceptions de r\u00e9acteurs modernes utilisent la circulation naturelle, un \u00e9l\u00e9ment de\u00a0<\/span><strong><span>s\u00e9curit\u00e9<\/span><\/strong><span>\u00a0tr\u00e8s important\u00a0.\u00a0De nombreux syst\u00e8mes de s\u00e9curit\u00e9 passive dans les conceptions de r\u00e9acteurs modernes fonctionnent sans utiliser de pompes, ce qui am\u00e9liore la s\u00e9curit\u00e9, l&#8217;int\u00e9grit\u00e9 et la fiabilit\u00e9 de la conception, tout en r\u00e9duisant simultan\u00e9ment le co\u00fbt global du r\u00e9acteur.<\/span><\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2><span>Indicateurs de circulation naturelle<\/span><\/h2>\n<p><span>Dans les REP, divers param\u00e8tres peuvent \u00eatre utilis\u00e9s pour indiquer ou v\u00e9rifier la circulation naturelle.\u00a0Cela d\u00e9pend du type d&#8217;installation et des syst\u00e8mes d&#8217;installation.\u00a0Par exemple, pour un PWR, les param\u00e8tres s\u00e9lectionn\u00e9s qui peuvent \u00eatre utilis\u00e9s sont les suivants:<\/span><\/p>\n<ul>\n<li><span>Id\u00e9alement, le\u00a0<\/span><strong><span>d\u00e9bit<\/span><\/strong><span>\u00a0peut \u00eatre mesur\u00e9 dans chacune des boucles.<\/span><\/li>\n<li><strong><span>\u0394T<\/span><\/strong><span>\u00a0(\u00a0<\/span><strong><span>T\u00a0<\/span><sub><span>chaud<\/span><\/sub><span>\u00a0&#8211; T\u00a0<\/span><sub><span>froid<\/span><\/sub><\/strong><span>\u00a0).\u00a0La diff\u00e9rence de temp\u00e9rature entre les jambes chaudes et les jambes froides doit \u00eatre de 25 \u00e0 80% de la valeur de pleine puissance et doit \u00eatre constante ou diminuer lentement.\u00a0Cela indique que la chaleur de d\u00e9croissance est \u00e9limin\u00e9e du syst\u00e8me \u00e0 un rythme ad\u00e9quat pour maintenir ou r\u00e9duire les temp\u00e9ratures \u00e0 c\u0153ur.<\/span><\/li>\n<li><span>Les temp\u00e9ratures des jambes chaudes et froides doivent \u00eatre stables ou diminuer lentement.\u00a0Encore une fois, cela indique que la chaleur est \u00e9limin\u00e9e et que la charge thermique de d\u00e9croissance diminue comme pr\u00e9vu.<\/span><\/li>\n<li><span>La pression de vapeur du g\u00e9n\u00e9rateur de vapeur (pression lat\u00e9rale secondaire) doit suivre la temp\u00e9rature du syst\u00e8me de refroidissement du r\u00e9acteur.\u00a0Cela v\u00e9rifie que le g\u00e9n\u00e9rateur de vapeur \u00e9limine la chaleur du liquide de refroidissement RCS.<\/span><\/li>\n<\/ul>\n<p><span>R\u00e9f\u00e9rence sp\u00e9ciale: Circulation naturelle dans les centrales nucl\u00e9aires refroidies par eau, IAEA-TECDOC-1474.\u00a0AIEA, 2005. ISBN 92\u20130\u2013110605 \u2013 X.<\/span><\/p>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Cet article est bas\u00e9 sur la traduction automatique de l&#8217;article original en anglais. Pour plus d&#8217;informations, voir l&#8217;article en anglais. Pouvez vous nous aider Si vous souhaitez corriger la traduction, envoyez-la \u00e0 l&#8217;adresse: translations@nuclear-power.com ou remplissez le formulaire de traduction en ligne. Nous appr\u00e9cions votre aide, nous mettrons \u00e0 jour la traduction le plus rapidement possible. Merci<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>La circulation naturelle est la circulation de fluide dans les syst\u00e8mes de canalisation ou les piscines ouvertes due aux changements de densit\u00e9 caus\u00e9s par les diff\u00e9rences de temp\u00e9rature.\u00a0G\u00e9nie thermique Circulation naturelle Circulation naturelle en boucle ferm\u00e9e La circulation naturelle\u00a0est la circulation de fluide dans\u00a0les syst\u00e8mes de canalisation\u00a0ou\u00a0les piscines ouvertes\u00a0due aux\u00a0changements de densit\u00e9\u00a0caus\u00e9s par les diff\u00e9rences &#8230; <a title=\"Qu&#8217;est-ce que la circulation naturelle &#8211; D\u00e9finition\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/\" aria-label=\"En savoir plus sur Qu&#8217;est-ce que la circulation naturelle &#8211; D\u00e9finition\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[8],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Qu&#039;est-ce que la circulation naturelle - D\u00e9finition<\/title>\n<meta name=\"description\" content=\"La circulation naturelle est la circulation de fluide dans les syst\u00e8mes de canalisation ou les piscines ouvertes due aux changements de densit\u00e9 caus\u00e9s par les diff\u00e9rences de temp\u00e9rature. G\u00e9nie thermique\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Qu&#039;est-ce que la circulation naturelle - D\u00e9finition\" \/>\n<meta property=\"og:description\" content=\"La circulation naturelle est la circulation de fluide dans les syst\u00e8mes de canalisation ou les piscines ouvertes due aux changements de densit\u00e9 caus\u00e9s par les diff\u00e9rences de temp\u00e9rature. G\u00e9nie thermique\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-08T17:35:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-17T07:31:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema-300x219.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture est.\">\n\t<meta name=\"twitter:data2\" content=\"8 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Natural-Circulation-schema-300x219.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/\",\"name\":\"Qu'est-ce que la circulation naturelle - D\\u00e9finition\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/#primaryimage\"},\"datePublished\":\"2019-10-08T17:35:04+00:00\",\"dateModified\":\"2020-02-17T07:31:04+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"La circulation naturelle est la circulation de fluide dans les syst\\u00e8mes de canalisation ou les piscines ouvertes due aux changements de densit\\u00e9 caus\\u00e9s par les diff\\u00e9rences de temp\\u00e9rature. G\\u00e9nie thermique\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-la-circulation-naturelle-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/43274"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/comments?post=43274"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/43274\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/media?parent=43274"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/categories?post=43274"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/tags?post=43274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}