{"id":44360,"date":"2019-10-15T07:25:35","date_gmt":"2019-10-15T06:25:35","guid":{"rendered":"https:\/\/www.thermal-engineering.org\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/"},"modified":"2020-02-19T07:54:15","modified_gmt":"2020-02-19T06:54:15","slug":"quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition","status":"publish","type":"post","link":"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/","title":{"rendered":"Qu&#8217;est-ce que le syst\u00e8me de chauffage d&#8217;alimentation en eau &#8211; R\u00e9g\u00e9n\u00e9ration thermique &#8211; D\u00e9finition"},"content":{"rendered":"<div class=\"su-quote su-quote-style-default\">\n<div class=\"su-quote-inner su-clearfix\">En g\u00e9n\u00e9ral, le syst\u00e8me de chauffage d&#8217;eau d&#8217;alimentation comprend les \u00e9l\u00e9ments suivants: r\u00e9chauffeurs d&#8217;eau d&#8217;alimentation \u00e0 basse pression, d\u00e9gazeur, r\u00e9chauffeurs d&#8217;eau d&#8217;alimentation \u00e0 haute pression.\u00a0Le syst\u00e8me pr\u00e9chauffe l&#8217;eau d&#8217;alimentation jusqu&#8217;\u00e0 230 \u00b0 C.\u00a0G\u00e9nie thermique<\/div>\n<\/div>\n<div class=\"su-divider su-divider-style-dotted\"><\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<div class=\"su-spacer\"><\/div>\n<h2>Syst\u00e8me de chauffage d&#8217;eau d&#8217;alimentation &#8211; R\u00e9g\u00e9n\u00e9ration thermique<\/h2>\n<p>En g\u00e9n\u00e9ral, le syst\u00e8me de chauffage de l&#8217;eau d&#8217;alimentation comprend:<\/p>\n<ul>\n<li>chauffe-eau \u00e0 basse pression<\/li>\n<li>d\u00e9gazeur<\/li>\n<li>chauffe-eau \u00e0 haute pression<\/li>\n<\/ul>\n<p><strong>R\u00e9chauffeurs d&#8217;eau d&#8217;alimentation basse pression<\/strong><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Condenser-LP-Heaters-Deaerator-min.png\"><img loading=\"lazy\" class=\"alignright size-medium wp-image-17843 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Condenser-LP-Heaters-Deaerator-min-300x146.png\" alt=\"Condenseur - Chauffe-eau LP - D\u00e9sa\u00e9rateur\" width=\"300\" height=\"146\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Condenser-LP-Heaters-Deaerator-min-300x146.png\" \/><\/a>Le\u00a0<strong>condensat<\/strong>\u00a0des\u00a0<strong>pompes \u00e0 condensat<\/strong>\u00a0passe ensuite par plusieurs \u00e9tages de\u00a0<strong>r\u00e9chauffeurs d\u2019eau d\u2019alimentation \u00e0 basse pression<\/strong>\u00a0, dans lesquels la temp\u00e9rature du condensat est augment\u00e9e par le transfert de chaleur de la vapeur extraite des turbines \u00e0 basse pression.\u00a0Il y a g\u00e9n\u00e9ralement trois ou quatre \u00e9tages de r\u00e9chauffeurs d&#8217;eau d&#8217;alimentation basse pression connect\u00e9s dans la cascade.\u00a0Le condensat sort des chauffe-eau d\u2019alimentation basse pression \u00e0 environ p = 1 MPa, t = 150 \u00b0 C et p\u00e9n\u00e8tre dans le\u00a0<strong>d\u00e9gazeur<\/strong>.\u00a0Le syst\u00e8me de condensat principal contient \u00e9galement un syst\u00e8me de purification m\u00e9canique du condensat pour \u00e9liminer les impuret\u00e9s.\u00a0Les r\u00e9chauffeurs d&#8217;eau d&#8217;alimentation s&#8217;autor\u00e9gulent.\u00a0Cela signifie que plus le d\u00e9bit d&#8217;eau d&#8217;alimentation est important, plus le taux d&#8217;absorption de chaleur par la vapeur est important et plus le d\u00e9bit de vapeur d&#8217;extraction est important.<\/p>\n<p>Il y a des clapets anti-retour dans les conduites de vapeur d&#8217;extraction entre les r\u00e9chauffeurs d&#8217;eau d&#8217;alimentation et la turbine.\u00a0Ces clapets anti-retour emp\u00eachent l&#8217;inversion de flux de vapeur ou d&#8217;eau en cas de d\u00e9clenchement de la turbine, ce qui provoque une diminution rapide de la pression \u00e0 l&#8217;int\u00e9rieur de la turbine.\u00a0Toute eau p\u00e9n\u00e9trant dans la turbine de cette mani\u00e8re pourrait endommager gravement ses aubes.<\/p>\n<p><strong>D\u00e9sa\u00e9rateur<\/strong><\/p>\n<figure id=\"attachment_17856\" class=\"wp-caption alignright\" aria-describedby=\"caption-attachment-17856\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Deaerator.png\"><img loading=\"lazy\" class=\"size-medium wp-image-17856 lazy-loaded\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Deaerator-285x300.png\" alt=\"D\u00e9sa\u00e9rateur\" width=\"285\" height=\"300\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Deaerator-285x300.png\" \/><\/a><figcaption id=\"caption-attachment-17856\" class=\"wp-caption-text\">Sch\u00e9ma d&#8217;un d\u00e9gazeur type \u00e0 plateau.\u00a0Source: wikipedia.org Licence: CC BY-SA 3.0<\/figcaption><\/figure>\n<p>Dans le\u00a0<strong>d\u00e9gazeur<\/strong>\u00a0, le condensat est chauff\u00e9 dans des conditions satur\u00e9es g\u00e9n\u00e9ralement par la vapeur extraite de la turbine \u00e0 vapeur.\u00a0La vapeur d\u2019extraction est m\u00e9lang\u00e9e dans le d\u00e9gazeur par un syst\u00e8me de buses de pulv\u00e9risation et de plateaux en cascade entre lesquels la vapeur s\u2019infolie.\u00a0Tous les gaz dissous dans le condensat sont lib\u00e9r\u00e9s au cours de ce processus et \u00e9vacu\u00e9s du d\u00e9gazeur par \u00e9vacuation dans l&#8217;atmosph\u00e8re ou le condenseur principal.\u00a0Juste en dessous du\u00a0<strong>d\u00e9gazeur se<\/strong>\u00a0trouve le\u00a0<strong>r\u00e9servoir de stockage d&#8217;eau d&#8217;alimentation<\/strong>, dans lequel une grande quantit\u00e9 d\u2019eau d\u2019alimentation est stock\u00e9e dans des conditions proches de la saturation.\u00a0Lors du d\u00e9clenchement de la turbine, cette eau d&#8217;alimentation peut \u00eatre fournie aux g\u00e9n\u00e9rateurs de vapeur afin de maintenir le stock d&#8217;eau requis pendant les p\u00e9riodes transitoires.\u00a0Le d\u00e9gazeur et le r\u00e9servoir de stockage sont g\u00e9n\u00e9ralement situ\u00e9s \u00e0 une altitude \u00e9lev\u00e9e dans le hall de la turbine afin de garantir une\u00a0<a title=\"T\u00eate d'aspiration positive nette\" href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/centrifugal-pumps\/net-positive-suction-head\/\">hauteur d&#8217;aspiration nette nette<\/a>\u00a0(NPSH)\u00a0ad\u00e9quate\u00a0\u00e0 l&#8217;entr\u00e9e des pompes d&#8217;alimentation.\u00a0<strong>NPSH<\/strong>\u00a0est utilis\u00e9 pour mesurer \u00e0\u00a0<strong>quel point<\/strong>\u00a0un fluide est\u00a0<strong>proche<\/strong>\u00a0de conditions satur\u00e9es.\u00a0L&#8217;abaissement de la pression du c\u00f4t\u00e9 aspiration peut provoquer une\u00a0<a href=\"https:\/\/www.nuclear-power.com\/nuclear-engineering\/fluid-dynamics\/centrifugal-pumps\/cavitation\/\"><strong>cavitation<\/strong><\/a>\u00a0.\u00a0Cette disposition minimise le risque de cavitation dans la pompe.<\/p>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\">\n<p><strong><span>Chauffe-eau haute pression<\/span><\/strong><\/p>\n<p><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Feedwater-Pumps-HP-Heaters-min.png\"><img loading=\"lazy\" class=\"lazy-hidden alignright size-medium wp-image-17847\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Feedwater-Pumps-HP-Heaters-min-300x298.png\" alt=\"Pompes \u00e0 eau d'alimentation - R\u00e9chauffeurs HP\" width=\"300\" height=\"298\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Feedwater-Pumps-HP-Heaters-min-300x298.png\" \/><\/a><span>La d\u00e9charge d&#8217;eau des pompes \u00e0 eau d&#8217;alimentation s&#8217;\u00e9coule \u00e0 travers les\u00a0<\/span><strong><span>chauffe-eau \u00e0 haute pression<\/span><\/strong><span>\u00a0, entre dans l&#8217;\u00a0<\/span><a title=\"B\u00e2timent de confinement\" href=\"https:\/\/www.nuclear-power.com\/nuclear-power-plant\/containment-building\/\"><span>enceinte de confinement<\/span><\/a><span>\u00a0, puis s&#8217;\u00e9coule dans les\u00a0<\/span><a title=\"G\u00e9n\u00e9rateur de vapeur\" href=\"https:\/\/www.nuclear-power.com\/steam-generator\/\"><span>g\u00e9n\u00e9rateurs de vapeur<\/span><\/a><span>\u00a0.<\/span><\/p>\n<p><span>Les\u00a0<\/span><strong><span>chauffe-eau haute pression<\/span><\/strong><span>\u00a0sont chauff\u00e9s par extraction de vapeur de la turbine haute pression HP Turbine.\u00a0Les drains des chauffe-eau haute pression sont g\u00e9n\u00e9ralement achemin\u00e9s vers le d\u00e9gazeur.<\/span><\/p>\n<p><span>L&#8217;eau d&#8217;alimentation (\u00a0<\/span><strong><span>eau 230 \u00b0 C; 446 \u00b0 F; 6,5 MPa<\/span><\/strong><span>\u00a0) est pomp\u00e9e dans\u00a0<\/span><strong><span>le g\u00e9n\u00e9rateur de vapeur<\/span><\/strong><span>\u00a0par l&#8217;entr\u00e9e d&#8217;eau d&#8217;alimentation.<\/span><\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\"><a href=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Steam-Turbine-scheme-min.png\"><img loading=\"lazy\" class=\"lazy-hidden size-large wp-image-17846\" src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Steam-Turbine-scheme-min-1024x529.png\" alt=\"Turbine \u00e0 vapeur de PWR 3000 MWth typique\" width=\"669\" height=\"346\" data-lazy-type=\"image\" data-src=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Steam-Turbine-scheme-min-1024x529.png\" \/><\/a><\/p>\n<figure id=\"attachment_17846\" class=\"wp-caption aligncenter\" aria-describedby=\"caption-attachment-17846\"><figcaption id=\"caption-attachment-17846\" class=\"wp-caption-text\"><span>Sch\u00e9ma d&#8217;une turbine \u00e0 vapeur d&#8217;un REP typique de 3 000 MWth.<\/span><\/figcaption><\/figure>\n<\/div>\n<\/div>\n<div class=\"lgc-column lgc-grid-parent lgc-grid-100 lgc-tablet-grid-100 lgc-mobile-grid-100 lgc-equal-heights  lgc-first lgc-last\">\n<div class=\"inside-grid-column\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.<\/p>\n<p>Cet article est bas\u00e9 sur la traduction automatique de l&#8217;article original en anglais. Pour plus d&#8217;informations, voir l&#8217;article en anglais. Pouvez vous nous aider Si vous souhaitez corriger la traduction, envoyez-la \u00e0 l&#8217;adresse: translations@nuclear-power.com ou remplissez le formulaire de traduction en ligne. Nous appr\u00e9cions votre aide, nous mettrons \u00e0 jour la traduction le plus rapidement possible. Merci<\/p>\n","protected":false},"excerpt":{"rendered":"<p>En g\u00e9n\u00e9ral, le syst\u00e8me de chauffage d&#8217;eau d&#8217;alimentation comprend les \u00e9l\u00e9ments suivants: r\u00e9chauffeurs d&#8217;eau d&#8217;alimentation \u00e0 basse pression, d\u00e9gazeur, r\u00e9chauffeurs d&#8217;eau d&#8217;alimentation \u00e0 haute pression.\u00a0Le syst\u00e8me pr\u00e9chauffe l&#8217;eau d&#8217;alimentation jusqu&#8217;\u00e0 230 \u00b0 C.\u00a0G\u00e9nie thermique Syst\u00e8me de chauffage d&#8217;eau d&#8217;alimentation &#8211; R\u00e9g\u00e9n\u00e9ration thermique En g\u00e9n\u00e9ral, le syst\u00e8me de chauffage de l&#8217;eau d&#8217;alimentation comprend: chauffe-eau \u00e0 basse &#8230; <a title=\"Qu&#8217;est-ce que le syst\u00e8me de chauffage d&#8217;alimentation en eau &#8211; R\u00e9g\u00e9n\u00e9ration thermique &#8211; D\u00e9finition\" class=\"read-more\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/\" aria-label=\"En savoir plus sur Qu&#8217;est-ce que le syst\u00e8me de chauffage d&#8217;alimentation en eau &#8211; R\u00e9g\u00e9n\u00e9ration thermique &#8211; D\u00e9finition\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[8],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Qu&#039;est-ce que le syst\u00e8me de chauffage d&#039;alimentation en eau - R\u00e9g\u00e9n\u00e9ration thermique - D\u00e9finition<\/title>\n<meta name=\"description\" content=\"En g\u00e9n\u00e9ral, le syst\u00e8me de chauffage d&#039;eau d&#039;alimentation comprend les \u00e9l\u00e9ments suivants: r\u00e9chauffeurs d&#039;eau d&#039;alimentation \u00e0 basse pression, d\u00e9gazeur, r\u00e9chauffeurs d&#039;eau d&#039;alimentation \u00e0 haute pression. Le syst\u00e8me pr\u00e9chauffe l&#039;eau d&#039;alimentation jusqu&#039;\u00e0 230 \u00b0 C. G\u00e9nie thermique\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Qu&#039;est-ce que le syst\u00e8me de chauffage d&#039;alimentation en eau - R\u00e9g\u00e9n\u00e9ration thermique - D\u00e9finition\" \/>\n<meta property=\"og:description\" content=\"En g\u00e9n\u00e9ral, le syst\u00e8me de chauffage d&#039;eau d&#039;alimentation comprend les \u00e9l\u00e9ments suivants: r\u00e9chauffeurs d&#039;eau d&#039;alimentation \u00e0 basse pression, d\u00e9gazeur, r\u00e9chauffeurs d&#039;eau d&#039;alimentation \u00e0 haute pression. Le syst\u00e8me pr\u00e9chauffe l&#039;eau d&#039;alimentation jusqu&#039;\u00e0 230 \u00b0 C. G\u00e9nie thermique\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-15T06:25:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-19T06:54:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Condenser-LP-Heaters-Deaerator-min-300x146.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Nick Connor\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture est.\">\n\t<meta name=\"twitter:data2\" content=\"3 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/\",\"name\":\"Thermal Engineering\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/www.thermal-engineering.org\/fr\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/thermal-engineering.org\/wp-content\/uploads\/2019\/05\/Condenser-LP-Heaters-Deaerator-min-300x146.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/#webpage\",\"url\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/\",\"name\":\"Qu'est-ce que le syst\\u00e8me de chauffage d'alimentation en eau - R\\u00e9g\\u00e9n\\u00e9ration thermique - D\\u00e9finition\",\"isPartOf\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/#primaryimage\"},\"datePublished\":\"2019-10-15T06:25:35+00:00\",\"dateModified\":\"2020-02-19T06:54:15+00:00\",\"author\":{\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\"},\"description\":\"En g\\u00e9n\\u00e9ral, le syst\\u00e8me de chauffage d'eau d'alimentation comprend les \\u00e9l\\u00e9ments suivants: r\\u00e9chauffeurs d'eau d'alimentation \\u00e0 basse pression, d\\u00e9gazeur, r\\u00e9chauffeurs d'eau d'alimentation \\u00e0 haute pression. Le syst\\u00e8me pr\\u00e9chauffe l'eau d'alimentation jusqu'\\u00e0 230 \\u00b0 C. G\\u00e9nie thermique\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.thermal-engineering.org\/fr\/quest-ce-que-le-systeme-de-chauffage-dalimentation-en-eau-regeneration-thermique-definition\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#\/schema\/person\/e8c544db9afedaec8574d6464f9398bb\",\"name\":\"Nick Connor\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.thermal-engineering.org\/fr\/#personlogo\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/84c0dec310b44b65da29dc9df6925239?s=96&d=mm&r=g\",\"caption\":\"Nick Connor\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/44360"}],"collection":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/comments?post=44360"}],"version-history":[{"count":0,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/posts\/44360\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/media?parent=44360"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/categories?post=44360"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermal-engineering.org\/fr\/wp-json\/wp\/v2\/tags?post=44360"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}